Electrolux ICON RHDFW60GS Specyfikacje - Strona 2
Przeglądaj online lub pobierz pdf Specyfikacje dla Okap wentylacyjny Electrolux ICON RHDFW60GS. Electrolux ICON RHDFW60GS 2 stron. 36" glass canopy wall-mount hood
Glass Canopy Wall-Mount Hood
RH36WC60GS
7
Air outlet - 7
/
8
4
9
/
"
16
36" Glass Canopy Wall-Mount Hood Specifications
Product Weight – 64 Lbs.
•
Wall-Mount Installation
•
Ventilation system is preset to exhaust air outside. If outside ducting is
•
not possible, optional Duct-Free Kit (PN # RHDFW60GS) is available
to convert ventilation to allow air to recirculate inside. (Refer to Ducted
Option Specifications for outside ventilation.)
Sones Rating – 9.9
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 0.474 kW (For use on
•
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 3.8 Amps
•
Always consult local and national electric codes. Check local building
•
codes for installation requirements, as they may vary per locale.
Minimum installation height allowed from bottom of hood to cooking
•
surface is 24" - 30" for electric and 30" for gas. (NOT more than 36"
recommended.)
To prepare mounting surface, adequate structure and support must be
•
provided, capable of supporting 100 lbs.
Electrolux Major Appliances, N.A.
USA
250 Bobby Jones Expressway
•
•
5855 Terry Fox Way
Mississauga, ON L5V 3E4
CANADA
•
•
RH36WC60GS 10/09
Top
" diam.
Wiring box
Controls
2
9
/
"
16
35
Augusta, GA 30907
1-877 -4electrolux (1-877 -435-3287)
•
1-800-265-8352
•
10
13
/
"
16
7
/
"
8
Ducted Option Specifications
For outside ventilation.
•
Exhaust Duct Required – 8" round
•
For most efficient airflow exhaust, use a straight run or as few elbows
•
as possible.
Use metallic flex ducting only to connect rigid duct directly to transitions
•
(if allowed by code).
Thermal breaks such as short section of nonmetallic duct, should be
•
used in areas of extreme cold.
Cold weather installations should have additional backdraft damper
•
installed.
Refer to installation instructions on web for detailed exhaust duct
•
preparation and converting vent blower system for recirculating inside.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
Duct-Free Kit – (PN # RHDFW60GS).
•
electroluxicon.com
•
electroluxicon.ca
•
© 2009 Electrolux Home Products, Inc.
13
3
/
"
16
30
Dimensions
min.
from base of
hood to ceiling,
54
and include
max.
clearance
required for
installation.
29
7
/
"
16
( min.
height
with one
cover)
19
11
/
"
16
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
1
/
"
8
9
/
"
16
Printed in the U.S.A.