Atlantic Ultraviolet Mighty Pure MP13A Instrukcja obsługi - Strona 9

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Systemy filtracji wody Atlantic Ultraviolet Mighty Pure MP13A. Atlantic Ultraviolet Mighty Pure MP13A 20 stron. Ultraviolet
Również dla Atlantic Ultraviolet Mighty Pure MP13A: Instrukcja obsługi (20 strony)

L
I
AMP
NSTALLATION OR
Step 2 - Remove End-Cap
Step 4 & 5 - Remove Sockets
1.
Disconnect power to water purifier.
2.
Remove both easy-off end caps by pulling each cap off static gland nut. Slide each end cap along the wire away
from the socket.
3.
Carefully withdraw lamp approximately 2 inches from chamber while feeding lamp socket and lead wire on
opposite end of chamber.
4.
While holding lamp end, carefully remove lamp socket on end now exposed.
5.
Next, carefully slide lamp back into chamber, until approximately 2 inches of the lamp is exposed on the opposite
end. Hold lamp and remove lamp socket.
6.
Lamp should now be disconnected on both ends. Carefully remove lamp from chamber. Be sure to withdraw
lamp straight out without angling until completely clear of quartz sleeve.
!
CAUTION:
replacing lamp.
7.
Reinstall lamp in reverse order.
!
WARNING:
water purifier until lamp and both easy-off end caps have been properly reinstalled.
R
EPLACEMENT
Figure 3 - Lamp Replacement
Lamp and quartz sleeve are easily damaged. Exercise care when removing or
Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to
Step 3 - Withdraw Lamp
Step 6 - Remove Lamp
9