Atlantic Ultraviolet MIN-9 Instrukcja obsługi - Strona 10
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Systemy filtracji wody Atlantic Ultraviolet MIN-9. Atlantic Ultraviolet MIN-9 16 stron. Germicidal ultraviolet water purifiers
Również dla Atlantic Ultraviolet MIN-9: Instrukcja obsługi (16 strony), Instrukcja obsługi (20 strony)
R
EPLACEMENT OF
!
CAUTION:
are worn when handling broken quartz sleeves.
1.
Disconnect power to water purifier, and remove ground connector from the chamber.
2.
Shut off water supply to water purifier via inlet and outlet shut off valves and drain chamber, if possible.
3.
Follow the steps in "LAMP INSTALLATION OR REPLACEMENT" to remove lamp.
4.
Unscrew static gland nuts from each end of the chamber. Avoid striking quartz sleeve with static gland nut.
5.
Remove Teflon
within the static gland nut. If so, remove Teflon
6.
Carefully remove as much of the broken quartz sleeve as possible, from each end of the chamber.
7.
To remove fragments of quartz sleeving, hold the purifier vertically and shake. The quartz fragments will
break and drop out of the purifier through the gland fitting. Flush water through chamber being careful to
remove all quartz fragments from the interior of the chamber.
8.
Carefully discard all pieces of the broken quartz sleeve.
9.
Align the end of the quartz sleeve with the gland fitting of the chamber.
10.
Carefully slide the quartz sleeve into the chamber, guiding it through the gland fitting. NOTE: Use care to
keep the quartz sleeve parallel to the chamber, angling the quartz sleeve in any direction could result in the
breakage of the quartz sleeve.
11.
As the quartz sleeve nears the far end of the chamber, support the quartz sleeve by inserting your finger
through the far end gland fitting and into the quartz sleeve. This will minimize the possibility of breaking the
quartz sleeve as it passes through the gland fitting.
12.
Center the quartz sleeve in the chamber, making sure the quartz sleeve protrudes an equal distance past each
threaded gland fitting, of the chamber.
Re-install o-rings, Teflon ® washers, and static gland nuts. Be sure O-rings are placed on quartz sleeve before
13.
Teflon ®
washer. Tighten static gland nuts firmly by hand only, DO NOT USE HAND TOOLS. Tightening
with hand tools is likely to cause quartz sleeve to break.
14.
When all connections are complete allow water to enter the water purifier at a low flow rate until the purifier
is pressurized. With the purifier pressurized, it should be checked for leaks.
15.
If no leaks occur, reinstall lamp.
D
M
ISPOSAL OF
Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added
lamps should not be placed in the trash. Dispose of properly.
For further information regarding the disposal and recycling of lamps containing mercury, along with Federal and State
requirements visit http://www.lamprecycle.org. Product Data Sheets for germicidal ultraviolet lamps can be found in the
"PDF Library for Ster-L-Ray
L
-O
P
AMP
UT
ROTECTION
If the ballast is plugged-in without a lamp or if the lamp fails, the ballast's lamp-out protection will prevent the ballast
from operating.
To reset: unplug the ballast and replace the lamp. The ballast must remain unplugged for two (2) minutes to reset.
After 2 minutes, plug the ballast back into the outlet receptacle it should resume proper operation.
10
B
Q
ROKEN
UARTZ
Broken Quartz is SHARP. It is recommended that protective goggles and gloves
®
washer and o-ring from both ends of quartz sleeve. Teflon
A
L
ERCURY
DDED
AMPS
TM
Germicidal Ultraviolet Lamps" section of http://www.ultraviolet.com.
S
LEEVE
®
washer from static gland nut before proceeding.
®
washer will some times remain