1 - Drilling the shelves:
a) Using the cardboard template
provided, and taking hole "B" as
a point of reference, drill the
shelves along the central axis to
allow the passage of the chimney.
The chimney must be inserted into
the shelves before it is fixed to the
hood canopy C (fig. 12).
b) When installing the ducting
version with the air outlet directed
upwards, if the ducting fan unit is
positioned below the line of
shelves it will be necessary to drill
a suitable hole in the top shelf only,
to allow the air ducting pipe to pass
through (fig. 13).
2 - Direction and position of the
ducting fan unit
a) The hood is normally supplied with
the air outlet directed towards the
wall (fig. 3), if it is to be installed with the air outlet directed
to the right or left (fig. 4a-b), it will be necessary to change
the direction of the ducting fan unit, proceeding as follows:
- Unscrew the screws U (fig. 14);
- Turn the ducting fan unit 60° to the right or left;
- Replace the screws U.
b) The ducting fan unit air outlets must be arranged
according to the type of installation to be carried out.
· Air outlet directed upwards (fig. 2a-b).
- Remove the plastic plug from the upper part of the venting
grill and replace it on the rear part (fig. 15).
· Air outlet directed towards the wall (fig. 3).
- Remove the plastic frame from the air outlet (fig. 16).
Part 1 - INSTALLATION INSTRUCTIONS
16
S36_12
12
S36_13
13
U
U
14
A08_14
15