PETROL ENGINE STARTING
OPERATION
1
Fill crankcase with oil as nominated in
engine manual.
-
Place your generator on level ground.
-
Remove plug or dipstick
-
Fill crankcase slowly to the point of
overflowing or correct level on dipstick.
Replace plug or dipstick securely.
2
Pull engine over several times to ensure there
has been no damage during transit.
3
Switch off electrical power outlets.
4
Turn fuel valve ON.
5
Close choke - push lever in direction of
arrow. It is normal to use the choke when
starting the generator from cold.
6
DO NOT ADJUST THROTTLE SETTING.
It has been factory set and locked at the
correct speed.
7
Set the ON/OFF switch to the ON position.
8
RECOIL/ROPE START - Pull the starter
handle until slight resistance is felt, then pull
briskly. Allow rope to recoil slowly.
ELECTRIC START - Press start button or turn
key to start. Do not operate starter for more
than about 10 seconds at a time.
Allow 60 seconds rest after 2 starting
attempts.
9
When engine starts, progressively OPEN THE
CHOKE until engine runs smoothly.
10 Allow engine to warm up for about 3 minutes
before applying high loadings to your welder.
11 If engine fails to start after several attempts,
fuel flooding may have occurred. Open the
choke, try starting engine several times, then
repeat starting procedure.
ADVANCED POWER GENERATING SETS
TO STOP ENGINE
-
Move start/stop switch or key to off position
DIESEL ENGINE
STARTING OPERATION
1
Fill crankcase with oil as nominated in
engine manual.
-
Place your generator on level ground.
-
Remove plug or dipstick
-
Fill crankcase slowly to the point of
overflowing or correct level on dipstick.
Replace plug or dipstick securely.
2
Pull engine over several times to ensure there
has been no damage during transit.
3
Set decompression lever if fitted
4
Turn fuel valve ON.
5
Set speed control to start setting, 50%
(refer engine owner's manual)
6
Set the ON/OFF switch to the ON position.
7
RECOIL/ROPE START - Pull the starter
handle until slight resistance is felt, then pull
briskly. Allow rope to recoil slowly.
ELECTRIC START - Press start button or turn
key to start. Do not operate starter for more
than about 10 seconds at a time.
Allow 60 seconds rest after 2 starting
attempts
8
Run engine at idle speed for 3 minutes to
allow it to warm up.
9
Set speed control to run position (Max)
before applying load.
(refer engine owner's manual)
TO STOP ENGINE
-
Turn fuel valve to off position, then turn
ignition key to off position.
5
OWNER'S GUIDE