Service
Preventing ESD problems
The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.
Maintenance Instructions
Service recommendations
Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guidelines:
■
Clean appropriate parts accurately
■
Replace any defective or worn parts
Preventive maintenance
Recommended interval between actions:
Valid at normal usage of the tool at a load up to 70% of maximum torque.
Service should only be carried out by trained technician following provided service instructions and
using original Atlas Copco spare parts.
Interval
1.500.000 cycles or 1 year
1.500.000 cycles
3.000.000 cycles
3.000.000 cycles
Service Equipment
■
Normal workshop equipment.
■
Necessary special equipment as shown in the exploded views/tables.
■
For testing a calibration rig is recommended.
■
PC with internet connection to be able to download necessary keys.
EN
© Atlas Copco Industrial Technique AB - 9839 1667 01
Action
Calibrate the tool
Exchange bit grounding
Exchange front part
Exchange motor
Service