Bose PowerMatch PM8500N Podręcznik użytkownika - Strona 38

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Wzmacniacz Bose PowerMatch PM8500N. Bose PowerMatch PM8500N 44 stron. Configurable professional power amplifier

Bose PowerMatch PM8500N Podręcznik użytkownika
User guide

About the Alarm log and Fault indicator

The PowerMatch™ amplifier monitors operating temperature, power supply status, amplifier status, open and short wiring, and
additional conditions for issues.
When issues are detected, information is stored in the amplifier in an internal log found by accessing
MAiN MeNU < UTiliTy < AlARM log from the front panel.
Information from the alarm log can also be viewed using ControlSpace
software is actively connected, either via USB or Ethernet, the time and date of the alarm condition is appended to the alarm log entry.
Locally stored alarm information is sent to ControlSpace Designer software upon connection.
Critical internal system-related issues are always considered faults and will trigger the fault-notification output and the Fault LED on the
front panel. However, you have the ability to select whether certain conditions are faults using ControlSpace Designer software. Refer to
the ControlSpace Designer software documentation for details on how to view and manage alarms.
The table below lists the fault conditions that you can elect to use.
Figure 21. Fault Conditions
Fault Category
Gain Reduction, Internal Protections
Gain Reduction, Signal Limiting
Output Fault
Input Fault
Input Fault
AC Power Fault
Page 38 User Guide
Captured Condition
System-Related Issue
Internal issue was detected.
Limiter Active
Limiter detected active for any output channel.
Open Circuit
An open circuit, output impedance is greater than
20 Ohms.
Input Clipping
Input signal found clipping.
Loss of Digital Audio Source
Digital audio source expected, but digital audio
source is not operational.
Loss of AC Power
AC Power below threshold. Set as default.
Designer™ software. In systems where ControlSpace Designer
®
Description
Power-off unit, check connections and airflow,
power-on unit and check.
Could be normal operation; check input sensitivity
and gains and output channel limiter settings.
Check loudspeaker cabling or Output Mute unused
channels. Use low impedance loudspeakers when in
MONO output mode.
Check and adjust input source, sensitivity settings,
and gain.
Check digital audio connections and source status.
Check AC mains for voltage sag. Consider moving
to more stable circuit.
pro.bose.com
Potential Solution
English