Drolet COMPAK EPA EXEMPT DB03060 Instrukcja obsługi - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Kuchenka Drolet COMPAK EPA EXEMPT DB03060. Drolet COMPAK EPA EXEMPT DB03060 19 stron. Drolet wood stove instructions and operations manual

CLEARANCES FROM COMBUSTIBLES

It is of outmost importance that the clearances to combustible materials be scrupulously
respected upon installation of the stove you have selected. Refer to the tables below :
A
B
29"
30"
Floor to ceiling height must be at least 7' (84") in all cases.
The clearance between the flue pipe and a wall are valid only for vertical walls and for
vertical flue pipe.
The flue pipe must not go through roof trussing, an attic, a wardrobe, a floor, a
combustible partition, or similar spaces.
A flue pipe crossing a combustible wall must have a minimum clearance of 18".
To reduce flue pipe clearances from combustible materials, contact your local safety
department.
For reduced clearances refer to NFPA 211 table 9-6.6.1.
Single pipe / Double pipe
C
D
39"
34-3/4"
E
F
22"
32"
6