DROPSA 3414050 Instrukcja obsługi i konserwacji - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Pompa wodna DROPSA 3414050. DROPSA 3414050 9 stron. Hydraulically controlled pump

7.4. USE
Check the setting data indicated on the control panel (if present).
Press the start button on the machine where the pump is connected.
Ensure that the pump starts.
Ensure the adequate lubrication of the machine (if there are doubts on correct operation, you can contact the Dropsa
S.p.A. Technical Office and ask for the testing procedure).
8. PROBLEMS AND SOLUTIONS
Below is a troubleshooting table where the main faults, probable causes and possible solutions to be carried out immediately
are indicated (contact Dropsa).
In the event of doubts and/or irresolvable problems, do not search for the fault disassembling parts of the pump, but rather
contact the Dropsa Technical Office.
FAULT
The pump does not
dispense lubricant or
does not dispense the
prescribed quantity.
The pump does not
dispense lubricant at the
prescribed pressure.
Operation may only be carried out by Dropsa specialised personnel.

9. MAINTENANCE PROCEDURES

The pump does not require special tools for any check and/or maintenance operations. In any case, it is recommended to use suitable
equipment and personal protective equipment (gloves, protection goggles, etc.) that in good condition in accordance with applicable
regulations to avoid injury or damage to parts of the pump.
The unit has been designed and built in such a way that it requires a minimum level of required maintenance. Nevertheless, it is
recommended to always keep the body of the equipment clean and periodically check the tube joints in order to be able to readily
detect any leaks.
ATTENTION: Before any maintenance or cleaning operation, make sure that hydraulic feed and electric power
are disconnected.
9.1. PUMP DISASSEMBLY
Empty the reservoir;
Disconnect the piping;
Loosen the securing screws;
Remove the reservoir, taking particular care for the models fitted with a grease pusher spring (could be loaded);
Remove the pump and any filters;
Unscrew the hydraulic cylinder from the pump, paying particular attention to the load the spring has;
Remove all the other components.
Before reassembling the pump, all the components should be washed with petroleum and lubricated.
TROUBLESHOOTING TABLE
CAUSE
The lubricant in the reservoir is
below the minimum level.
The pump control solenoid valve
does not vent.
Air bubbles in the lubricant.
The fittings are loose.
The piston of the pumping element
is worn out.
The delivery valve is blocked.
The pressure regulation of the
incoming control oil is incorrect.
REMEDIAL ACTION TO BE TAKEN
Top up the reservoir without exceeding the MAX level line.
Ensure that the pump control solenoid valve is a 3-way
valve for single acting pumps or 4-way for dual acting
pumps. Also ensure that the oil in the pump chamber
discharges regularly.
Open the bleed valve and activate the pump according to
the manual operating cycle until lubricant comes out of
the connection without any air bubbles. Close the valve.
You can manually press the cartridge itself in order to
favour priming of the pumping unit.
Carefully tighten all the fittings, ensuring that there are
no leaks.
Replace the piston
.
Replace the valve
.
Appropriately regulate the oil pressure as prescribed by
the general characteristics and bearing in mind the
compression ratio.
6