13. HANDLING AND TRANSPORTATION

Prior to shipping, the equipment is carefully packed in a cardboard package. During transportation and
storage, pay attention to the side on the cardboard packing. On receipt, check that the packing is not
damaged. Then, storage the machine in a dry location.
o As the panel is small and not heavy, it is not necessary the use of material handling equipment. Lift the
equipment observing the right way up shown on the cardboard packing.
o During storage, machine components can withstand temperatures –20 °C ÷ +50 °C (-4 °F ÷ +122 F°).
However, in order to avoid damages, machine starting should occur at a minimum temperature of +5 °C
(+41 °F).

14. OPERATING HAZARDS

WARNING: It is necessary to carefully read about the instructions and the risks involved in
the use of lubrication machines. The operator must know the machine
functioning through the User and Maintenance Manual.
Power supply
Any type of intervention must not be carried out before unplugging the machine from power supply. Make
sure that no one can start it up again during the intervention. All the installed electric and electronic equipment,
reservoirs and basic components must be grounded.
Inflammability
The lubricant generally used in lubrication systems is not normally inflammable. However, it is advised to avoid
contact with extremely hot substances or naked flames.
Pressure
Prior to any intervention, check the absence of residual pressure in any branch of the lubricant circuit as it may
cause oil sprays when disassembling components or fittings.
Noise
Pump does not produce excessive noise, less than 70 dB(A).
WARNING: Empty the reservoir, before the replaicing of the mini-pumps.

15. PRECAUTIONS

No particular operating hazards characterize VIP4Tools/Oil Panel, except for the following precautions:
Operator's contact with fluid in case of piping breaking/opening or contact with oil during filling
up/maintenance. The operator must be provided with suitable personal protective clothing (tit. VIII –
626).
Unnatural posture.
Use of incompatible lubricant.
Main unauthorized fluids:
Lubricants containing abrasive components
Lubricants containing silicon
Petrol – solvents – inflammable liquids
Corrosive products
Water
Food Products
8
Fluids
Dangers
Premature wear of pump
Pump failure
Fire – explosion –seal damage
Pump damage - danger to persons
Pump oxidization
Contamination of the product