DROPSA VIP4Tools Coaxial Instrukcja obsługi i konserwacji - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Systemy smarowania DROPSA VIP4Tools Coaxial. DROPSA VIP4Tools Coaxial 11 stron.

6.8 ELECTRIC WIRING
WARNING: At the end of all connecting operations, make sure that pipes and wires are safe from impacts
and carefully fixed.

7. INSTRUCTIONS FOR USE

7.1 PRIOR TO MACHINE START-UP
Verify the unit is undamaged.
Check that coaxial, pneumatic, hydraulic and electric connections have been carefully carried out.
Refill the reservoir with compatible lubricant.
Verify power supply: MAX 220VAC.
RESERVOIR REFILL
Use ONLY compatible lubricant and refill the reservoir by means of the oil refill plug provided with a filter. Do not pour
lubricant directly into the reservoir without using this oil refilling plug.
7.2 MACHINE START-UP
In order to avoid damage to the machine, the unit must be working when a minimum working temperature of +5°C
(+41°F) is reached.
Supply the pumps with a proper pneumatic source.
Start a lubrication cycle.
Verify panel operation.
If the panel is provided with a timer kit (optional), set machine parameters.
Discharge residual air from the pump, by means of the discharge valve located between the fixing
screws, until lubricant comes out (do not over-tighten the discharge valve). To facilitate air
discharge, adjust the pump at the maximum flowrate and carry out some lube cycles.
Adjust nominal flowrate by turning pump caps (see table par. 7.4).
Verify that lubrication is carried out correctly.
COAXIAL VERSION
6