DROPSA VIP4ToolsPro Instrukcja obsługi i konserwacji - Strona 12

Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Systemy smarowania DROPSA VIP4ToolsPro. DROPSA VIP4ToolsPro 12 stron.

Characteristic
Pressure at point of connection
Max. quantity of particles in suspension
Max. diameter of particles
Dew point
Max. quantity of oil in suspension
Whenever not utilizing natural base oils compatible with existing health regulations, it is necessary to adjust
the mixer pressure so as to avoid the formation and dispersion of oil mist into the environment.
The mixing pressure is indicatively between 1 bar (14.7 psi ) and 2.5 bar (36.7 psi).

14. CONTRAINDICATIONS

The VIP4ToolsPro panel does not have any particular contraindications except for the following points:
The operator coming into contact with fluid due to breakage/opening of supply tubing.
The operator must be furnished with suitable personal protection clothing/equipment (according to
current regulation).
Abnormal posture.
Take note of the indications shown in paragraph 6.2.
Contact with oil during filling/maintenance.
The operator must be furnished with suitable personal protection clothing/equipment (according to
current regulation).Use of unsuitable lubricants.
Main inadmissible fluids.
Lubricants with abrasive additives
Lubricants with silicon based additives
Petrol – solvents – flammable liquids
Corrosive products
Water
Food substances
Fluid
Requirement
Min. 6 Bar (88.2 psi)
15 mg/Nmc
0.05
2° C (35.6 °F)
5 mg/Nmc
Danger
High wear rate of contacted parts
Seizure of the pump
Fire – explosion – damage to seals
Corrosion of the pump– injury to persons
Oxidation of the pump
Contamination of the substances themselves
12