(5) Wrist Strap
Use Wrist Strap with tool for more convenient and safer operation and store.
(6) S Waist Hook
Use S Waist Hook to fix tool for more convenient and safer operation and carry.
(7) Buzzer beep and LED light Indication Light:
Operation status
Voltage 17V~17.5V
Voltage under 17V
Torque reached stop
Over current protection
Over temperture
protection
Low rpm protection
Stall protection
Battery ID error
(8) Torque Adjustment Light:Five sections Bit torque setting
1).Will Forward/Reverse Lever Cut to the middle position。
2).Pressing a bit start switch button at the Wake screwdriver。
3).Pressing Torque Adjustment Light Approximately 5 seconds, Torque identification light starts
flashing, then press the torque adjustment knob to adjust the desired torque.
4).Adjust the desired torque,Pressing Torque Adjustment Button Approximately 5 seconds., LED
stops flashing and at Approximately 5 seconds after the off, adjustment is completed.
5).Confirm torque, turn the switch to the forward or reverse position, then press the trigger switch
to view the torque light is lit selected by you.
6).Torque light as illustration, the left most light means min. torque output, then the torque output
increases gradually from left to right, the light of right most means max. torque.
2.
Please pay attention when operating the rechargeable screwdriver. Do not drop or abuse the
screwdriver.
3.
Not allow to turn the switch during operation in order to cause system malt-function.
4.
During operation, the Forward/Reverse switch has been changed accidentally that the device will
enable its self-protecting mode which is power off. Re-start the tool when this happen.
5.
When switches Forward/Backward switch during the screwdriver still operating, the protection
mechanism will be triggered and cause the motor to stop. Restart the screwdriver again will
change back to normal.
6.
Each operational torque setting, using time and frequency may result in different level of wear
and tear, at higher torque setting and use extensively could accelerate the wearing down of tool.
After one month, the torque is getting reduce gradually at the rate of 2~3% or 3~5 %( max
torque). The longer use of the device, torque reduction will become stable and the users could
measure the torque by a tester on a regular time schedule to check if the torque power still meets
the criteria.
LED Lights
Red light flashing continue
Red light continue
Green light flashing 1 time
Red light flashing 6 times
Red light flashing 9 times
Red light flashing 3 times
Red light flashing 3 times
Red/Green light flashing continue
7
Buzzer Beep
Beep continue
2 short and 1 long Beep
continue
Beep 1 time
Beep 6 times
Beep 9 times
Beep 3 times
Beep 3 times
Beep continue