Drucker Diagnostics Horizon 6 Flex Instrukcja obsługi - Strona 4

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Sprzęt laboratoryjny Drucker Diagnostics Horizon 6 Flex. Drucker Diagnostics Horizon 6 Flex 14 stron.
Również dla Drucker Diagnostics Horizon 6 Flex: Instrukcja serwisowa (10 strony)

Drucker Diagnostics Horizon 6 Flex Instrukcja obsługi
M
D
ODEL
ESCRIPTION
HORIZON is a versatile line of centrifuges pre-programmed with the most convenient cycle settings for ease of use.
Cycle settings can be changed to accommodate custom settings.
This general-purpose laboratory centrifuge may also be used to spin approved containers with biologics, chemicals
(non-flammable, non-explosive, non-volatile, and non-highly reactive), and environmental samples.
F
EATURES
o The first cycle is conveniently pre-set and labeled for your lab's most common applications. Use the default cycles
or customize them as needed.
o If desired, the control panel can be temporarily locked on one cycle, ideal for standardization to a single spin.
o Up to 10 cycles can be programmed for time, speed, and braking and labeled with a custom name. Cycles can be
programmed by g-force (RCF) rather than speed to facilitate matching validated cycles and manufacturers IFUs.
o Lid lighting indicates the centrifuge's status (ready, running, done), informing the operator when tubes are ready
for the analyzer and preventing tubes from being left in the centrifuge longer than necessary (patent pending).
o A traditional audible alert indicates the completion of the cycle. The audible alert can be muted.
o Cool–Flow design prevents overheating of samples by using ambient air to keep specimens at room temperature.
o The tube holders are fiber reinforced for high strength, durability, and years of trouble-free use.
o A clear lid permits safe observation of samples and optical calibration of speed.
o The lid safety system prevents the centrifuge from operating unless the lid is closed and latched.
o The lid safety system only allows entry into the centrifuge after the rotor has completely stopped.
o The high-power brushless motor provides years of operation with no routine maintenance.
I
U
NTENDED
SE
General purpose laboratory centrifuge, intended for the density-based separation of fluids through centripetal
acceleration.
W
ARRANTY
Drucker Diagnostics warranties that this centrifuge is free from defects in workmanship and parts for 2 years.
Drucker Diagnostics – Customer Service: +1-814-692-7661 –