Annovi Reverberi AR252 Instrukcja obsługi - Strona 19
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Annovi Reverberi AR252. Annovi Reverberi AR252 20 stron. 650 rpm - semi-hydraulic two diaphragm pump
Również dla Annovi Reverberi AR252: Specyfikacja (4 strony), Instrukcja obsługi (18 strony)
Problem
Oil on pump body or base.
Pump using too much oil (oil
flowing from delivery port) or oil
whitish in colour (water/oil emul-
sion in tank).
(1) Operations which must be carried out at an authorised service centre
English language
TROUBLESHOOTING
Cause
Oil seal on pump
shaft worn.
Oil pressure inside pump too high.
One or more diaphragms ruptured.
38
Remedy
Replace the worn oil seal. (1)
Restore correct oil level in tank.
Stop the pump at once. Replace
the diaphragms (1)
Use and Installation
8