Annovi Reverberi XJW2G25D-F27 Instrukcja obsługi i instrukcja części zamiennych - Strona 11
Przeglądaj online lub pobierz pdf Instrukcja obsługi i instrukcja części zamiennych dla Pompa wodna Annovi Reverberi XJW2G25D-F27. Annovi Reverberi XJW2G25D-F27 18 stron. Plunger pumps
Operating Instructions and Parts Manual
Plunger Pumps
replacement of worn seals will insure
peak operating performance and
trouble free operation. The water
seals and their respective components
sometimes referred to as the packing
stack, will vary slightly between models.
But the constant between models is
that the packing stack will consist of the
following items:
Piston Guides - which usually house the
low-pressure seal
Low-Pressure Seals
Piston Guide O-rings
High-Pressure Seals
Support Rings
Torque Ratings Inch Pounds (ft.
lbs.)
Head
Valve Cap
Oil
- AR64545 - Container is 4.5 fluid
ounces. Specially formulated for the
demands of the SJ and XJ series pump.
See parts breakdown.
NOTE: No other oil is factory approved
for this pump. Using any other oil may
result in Drive End Damage.
Winter or Long Time Storage
Available from Allparts Equipment and Accessories - 1-877-475-5660 - www.allpartsinc.com
443 (37)
443 (37)
SJ & XJ Series Pumps
1.
Drain all of the water out of the
pump.
2.
Run a 50% solution of a RV or
non-toxic/biodegradable antifreeze
through the pump.
3.
Flush the pump with fresh water
before the next use.
4.
In freezing conditions failure to
do this may cause internal pump
damage.
5.
For long periods of storage in
non-freezing areas the solution
will keep the seals and O-rings
lubricated.
NORTH
AMERICA
First Choice When Quality Matters