Dry-Matic DM01D Instrukcja obsługi - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Kontroler temperatury Dry-Matic DM01D. Dry-Matic DM01D 16 stron. Digital controller
It is recommended these units are installed by a preferred installer, please
contact us for a list in your area. Installation instructions are a guide only.
All electrical connections are subject to NZ law.
Pre-Installation checks
Before starting the installation, check the site & establish the best position/s of
the following components:
Diffuser
For most small to medium sized homes a single diffuser is usually all that
is necessary. It is recommended this be installed into a hallway that is common
to most rooms in the home. Installation of the main diffuser into the living /
dining area is not recommended.
Unit
The Unit comprises of the Fan, Heater (if supplied) and Filter box. It is
important to install the Unit so that it is as high as possible in the roof space,
this is to maximize the benefit of any thermal gain. It also keeps the fan inlet
air above dust which may come from the roof insulation. IMPORTANT: The
unit must be installed in a perfectly horizontal position to ensure correct heater
operation.
Attic Controller
best measure the inlet air condition (temperature) of the unit. The attic controller
must be installed vertically, with the pack glands downwards. The attic
controller can be fixed to the timber framing in the roof space.
Hall Controller
Hall controller is to be installed in the house at least 3m from the
diffuser but in the same area, approx. 1.5m above the floor. The hall controller
should not be installed on an external wall, in a living / dining area or in the
immediate vicinity of a heater or heat pump outlet. This is so that the Hall
Controller's built in temperature sensor is not affected by outside air temperature
or heating, and should best measure average house temperatures.
Ducting
Installation of ducting should allow for a full stretch and a smooth sweep
onto the rear of the diffuser. This will have a marked effect on the effective
operation of the unit air flow & attenuation of fan noise.
Installation Procedure
Based on the above criteria:
1. Fit Diffuser
Before cutting hole for diffuser, check that it will clear ceiling
joists and roof structure. Use circle template to cut correct sized hole in the
ceiling. Attach duct to grille, taping the centre duct sleeve to the grille spigot
then separately taping the insulation/outer to the spigot. Feed ducting through
the hole and clip diffuser in place using the spring clips. Ensure grille has a
minimum gap of 16mm between inner disk and outer collar.
6
DM - Operating Instructions, Installation Instructions, Wiring diagrams
Dry-Matic Installation Instructions
Is to be installed at the same level as the inlet to the fan, so as to
Version 3.1.765 August 2019