Speci cations
FTKS71/85H
Indoor unit
Model name
Outdoor unit
kW
Rated (Min.-Max.)
Capacity
Btu/h
24,200 (9,200-29,700)
Power supply
Running current
Rated
A
Power consumption
Rated
W
COP
Rated
W/W
Indoor unit
Front panel colour
Air ow rate (H)
m
/min (cfm)
3
Fan speed
Sound pressure level (H/L/SL)
dB (A)
Dimensions (H x W x D)
mm
Machine weight
kg
Outdoor unit
Casing colour
Type
Compressor
W
Motor output
Refrigerant charge (R-410A)
kg
Sound pressure level (H/SL)
dB (A)
Dimensions (H x W x D)
mm
Machine weight
kg
Operation range
CDB
Liquid
Piping
Gas
mm
connection
Drain
Max. piping length
m
Max. height di erence
Note: The above values are based on operation with a 220V, 60Hz power suuply.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Sound pressure levels are measured in an anechoic chamber based on temperature condition 1 above. These values are normally
operation as a result of ambient conditions.
FTKS71HVM
FTKS85HVM
RKS71HVM
RKS85HVM
7.1 (2.7-8.7)
8.5 (3.0-9.7)
29,000 (10,200-33,100)
1 phase, 220-240 V / 220-230 V, 50/60 Hz
9.6
11.6
2,060
2,540
3.45
3.35
FTKS71HVM
FTKS85HVM
White
21.7 (766)
23.0 (812)
5 steps, quiet and automatic
46/37/34
49/40/37
340 x 1,200 x 240
17
RKS71HVM
RKS85HVM
Ivory white
Hermetically sealed swing type
1,920
2,030
2.0
2.7
52/49
55/52
770 x 900 x 320
990 x 940 x 320
60
73
19.4 to 46
9.5
15.9
O.D. 16.0
30
15
20
somewhat higher during actual
17
Indoor unit
No.
Item
1
Wired remote controller
*
1
Length 3 m (shielded wire)
2
Wired remote controller cord
Length 8 m (shielded wire)
3
5-room centralised controller
*
2
*
3
Wiring adaptor for time clock/remote controller
4
(Normal open pulse contact/normal open contact)
5
Titanium apatite photocatalytic air-purifying lter
*
4
6
Remote controller loss prevention with chain
Notes: *1. The 3m (BRCW901A03) - or 8m (BRCW901A08) - length wired remote controller cord is required.
*2. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*3. The time clock and other devices should be obtained locally.
*4. The lter is a standard accessory. It should be replaced approximately every 3 years.
Titanium apatite photocatalytic
Titanium apatite photocatalytic
air-purifying lter
air-purifying lter
KAF970A48
KAF970A46
5-room centralised
Remote controller loss
controller
prevention with chain
KRC72
KKF917A4
Outdoor unit
No.
Item
1
Air direction adjustment grille
2
Drain plug
Note: *1. One set includes 5 pieces for 5 units.
Air direction adjustment grille
Drain plug
KPW945A4
KKP937A4
Control system
No.
Item
1
Central remote controller
*
1
*
2
Uni ed On/O controller
1
3
Schedule timer
*
1
4
Interface adaptor for DIII-NET use
Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
Central remote controller
DCS302CA61
Options
FTKS25/35G
FTKS50/60H
FTKS71/85H
BRC944B2
–
BRCW901A03
–
BRCW901A08
–
KRC72
KRP413AB1S
KAF970A46
KAF970A48
KKF917A4
RKS25/35EB
RKS50/60H
RKS71H
KPW937A4
KPW945A4
K
K
P
9
3
7
A
4
*
K
K
P
9
4
5
A
4
1
Drain plug
KKP945A4
FTKS25/35G, FTKS50/60/71/85H
DCS302CA61
DCS301BA61
DST301BA61
KRP928BB2S
Uni ed On/O controller
Schedule timer
DCS301BA61
DST301BA61
Speci cations are subject to change.
18
RKS85H
KPW5E112