DRYDEN AQUA DA-GEN Podręcznik użytkownika - Strona 8

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Falownik DRYDEN AQUA DA-GEN. DRYDEN AQUA DA-GEN 9 stron.
Również dla DRYDEN AQUA DA-GEN: Podręcznik użytkownika (13 strony)

DRYDEN AQUA DA-GEN Podręcznik użytkownika
110-230 V
DRY CONTACT
max. 3.15 A
1 2 3 4 5 6
7 8 9
10 11 12 13 14
LIGHT
Lighting control
9
&
10
110-230 V
DRY CONTACT
max. 3.15 A
1 2 3 4 5 6
7 8 9
10 11 12 13 14
AUX 3
AUX 1
3
4
&
11
&
12
APF dosing pump
AUX 4
Heating control
13
&
AUX 2
5
6
&
Automatic
backwash valve
(Besgo)
The auxiliary relays are configured
by default. If you want to reassign
the relays for other accessories, you
must access the "Service Menu".
Contact your authorized installer.
8.1
8.6
8.10
6.1
6.4

7. AUXILIARY RELAYS

7.1
7.4
14
7.3

8. SYSTEM SETTINGS

8.2
8.3
8.7
8.8
8.11
8.12
6. LIGHTNING
6.2
6.5
6.4 LED spotlight: In case of having installed led lights in your pool, use
this menu to set the lighting.
6.5 From this menu you can change the color of the lights in your pool.
Select the length of the sign in seconds in Pulse length and press Next
Program option to apply the pulse. Refer to your LED spotlight manual to
set its different colors.
7.2
7.5
7.4 Automatic mode: ON/OFF according to a timer that adjust the start and
end of the program. The timers can be configured with a frequency: Daily;
Every 2 days; Every 3 days; Every 4 days; Every 5 days; Weekly; Every 2
weeks; Every 3 weeks; Every 4 weeks.
7.5 Timer mode: Working time is programmed in minutes. Each time the
key on the front panel in relation to the relay is pressed, it will start up for
the time programmed. This function is recommended for the timing of air
pumps for spas.
7.6
7.6 Rename relays: It is posible to rename each auxiliary relay to suit
the use you want to assign. By pressing the plus/minus keys, a pop-up
keyboard will appear. Scroll up and down with the up/down keys and left
to right with the plus/minus keys. To select a letter press the OK.
8.4
8.9
8.9 Sound: Programming of the system to emit sound for the
functions: Keyboard (keys); Notices (pop-up message); Alarms
(working alarm); Filtration (start of the filtration).
8.11 Password: Allows to protect the access to the user´s
menu by activating a password. To enter your password press
a combination of 5 keys and the system will memorize. If you
forget the password, there is a "master password". Ask your
installer/provider.
8.13
2x
5
6.3
6.1 Lighting
6.2 Manual Mode (ON/OFF).
6.3 Automatic Mode: Shuts lights ON/OFF
according to a timer. The timers can be
configured with a frequency: Daily; Every 2
days; Every 3 days; Every 4 days; Every 5
days; Weekly; Every 2 weeks; Every 3 weeks;
Every 4 weeks.
7.3
7.1 Auxiliary relays:
7.2 It is possible to control up to 4 extra auxiliary
relays (water features, fountains, automatic
irrigation systems, built-in cleaning systems,
air pumps for spas, garden lighting, etc.). This
menu displays the relays which are still available
on your device and allow configuration.
7.3 Manual mode (ON/OFF).
8.5
8.3 Setting of preferred language.
8.5 Setting of day and current time.
8.7 Setting of the intensity of the
display lighting (0-100%) and
programming its ON/OFF time.
8.14
8.12 Cell hours: The system
memorizes the operation times of
the different modules.
8.14 System info: Information about
the available software version of the
TFT display and the power module.
It also shows the ID node which is
necessary for the configuration of
the WIFI connection of the system.