3M Static Monitor 790 Podręcznik użytkownika - Strona 15
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Przyrządy pomiarowe 3M Static Monitor 790. 3M Static Monitor 790 19 stron.
Accuracy
8.0 Parts Included
1 ea. 3M
Static Monitor 790
™
1 ea. User's Guide
1 ea. Mounting Plate with removable foam tape
1 ea. AC Adaptor
2 ea. Chassis/Ground Cords
1 ea. Two-wire Connector
9.0 Required Accessories and Optional Available Parts
Model No.
Description
2368VM
3M
Dual Conductor Fabric Wrist Band
™
2360
3M
Dual Conductor Coil Cord
™
2370
3M
Dual Conductor Coil Cord
™
2371
3M
Dual Conductor Coil Cord
™
3057
3M
Stand-By Jack
™
790VK
3M
Verification Kit
™
724P
3M
Power Supply Replacement AC Adapter
™
The following parameters are valid for altitudes up to 2000 m. Pollution
degree 2, Class 3, Equipment:
Voltage Detection Levels: 1V ±15%; 3V, 6V, and 9V ±10%
Ground Disconnect: 10Ω ±20%
Environmental Operating Conditions:
Temperature: Maximum 104°F, (40ºC) Minimum 50°F (10ºC)
Humidity: Maximum 75% R.H.
15
Size
adjustable
5 ft. (1.5m)
10 ft. (3.0m)
20 ft. (6.1m)
1.9 x 1.3 x 1.1 in. (4.8 x 3.3 x 2.8cm)