Dismantling or working on any component in the air dryer or the compressed air system under
pressure may cause serious personal injury and equipment failure. Before dismantling any part of
the air dryer or compressed air system completely vent the internal pressure to the atmosphere.
Only qualified service persons should attempt to work on the air dryer.
NORMAL MAINTENANCE PROCEDURES AND CHECKS
1. Daily Maintenance
• Check the operation of the automatic drain valves at least once during each eight
hour shift.
• Check Dewpoint Indicator to make sure it is the proper range
• Check suction pressures gauge to make sure it is the proper range.
• Make sure condenser coil is clean and unobstructed.
• Make sure the high temp warning light is not on.
2. Weekly Maintenance
• Clean Air cooled condenser coils - Blow off all dust and dirt that is on the condenser
fins with a compressed air maintenance gun.
• While cleaning the condenser fins do not damage fins.
WARNING - DRYER FAILURE DUE TO A DIRTY CONDENSER IS
NOT COVERED UNDER WARRANTY
3. Condensate Drain Maintenance
• Push the Push to Test Button to verify drain operation.
• Check the open time.
• Check the closed time.
If drain is not opening the drain should be dis-assembled, cleaned and checked for defects.
DANGER – This should only be done by a qualified service technician.
• Close the isolation valve before the drain.
• Remove the power unit and timer.
• Remove solenoid coil.
• Dis-assemble valve and check for debris and or defective spring or valve parts.
• Clean out any debris and re-assemble the valve.
• If there are defective or broken valve parts contact your distributor for a new drain valve.