Daikin Altherma 3 R F Instrukcja instalacji - Strona 9

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Centrale wentylacyjne Daikin Altherma 3 R F. Daikin Altherma 3 R F 12 stron.
Również dla Daikin Altherma 3 R F: Instrukcja obsługi (12 strony), Podręcznik użytkownika (20 strony), Instrukcja obsługi (16 strony), Instrukcja obsługi (16 strony)

Daikin Altherma 3 R F Instrukcja instalacji
WARNING
▪ Do NOT use locally purchased electrical parts inside
the product.
▪ Do NOT branch the power supply for the drain pump,
etc. from the terminal block. This could result in
electrical shock or fire.
WARNING
Keep the interconnection wiring away from copper pipes
without thermal insulation as such pipes will be very hot.
DANGER: RISK OF ELECTROCUTION
All electrical parts (including thermistors) are powered by
the power supply. Do not touch them with bare hands.
DANGER: RISK OF ELECTROCUTION
Disconnect the power supply for more than 10  minutes,
and measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing. The
voltage MUST be less than 50 V DC before you can touch
electrical components. For the location of the terminals,
see the wiring diagram.
b
c
d
e
f
DC+
DC-
h
a
a
Multimeter (DC voltage range)
b
S80 – reversing solenoid valve lead wire
c
S70 – fan motor lead wire
d
LED
e
S90 – thermistor lead wire
f
S20 – electronic expansion valve lead wire
g
S40 – thermal overload relay lead wire – high pressure
switch
h
DB1 – diode bridge
5.1

About electrical compliance

Only for ERLA03DAV3
Equipment
complying
with
International Technical Standard setting the limits for harmonic
currents produced by equipment connected to public low-voltage
systems with input current ≤16 A per phase.).
5.2
Guidelines when connecting the
electrical wiring
Tightening torques
Outdoor unit:
Item
M4 (X1M)
M4 (earth)
5.3
To connect the electrical wiring on
the outdoor unit
1 Remove the service cover.
2 Open the wire clamp.
ERLA03DAV3
Daikin Altherma 3 R
4P596797-1 – 2019.10
g
EN/IEC  61000‑3‑2
(European/
Tightening torque (N•m)
1.2~1.5
1.2~1.5

6 Finishing the outdoor unit installation

3 Connect the interconnection cable and power supply as follows:
a
a
Interconnection cable
b
Power supply cable
c
Circuit breaker
d
Earth leakage circuit breaker
e
Power supply
f
Earth
4 Tighten the terminal screws securely. We recommend using a
Phillips screwdriver.
6
Finishing the outdoor unit
installation
6.1
To finish the outdoor unit
installation
DANGER: RISK OF ELECTROCUTION
▪ Make sure that the system is earthed properly.
▪ Turn off the power supply before servicing.
▪ Install the service cover before turning on the power
supply.
1 Insulate and fix the refrigerant piping and cables as follows:
d
c
a
e
b
f
g
a
Gas pipe
b
Gas pipe insulation
c
Interconnection cable
d
Field wiring (if applicable)
e
Liquid pipe
f
Liquid pipe insulation
g
Finishing tape
2 Install the service cover.
7

Starting up the outdoor unit

See the indoor unit installation manual for configuration and
commissioning of the system.
50 Hz
c
d
220-240 V
b
e
f
Installation manual
9