for deterioration or wear of the ceramic rope seal. Replace defective seals.
16 - Inspect and clean your chimney and single wall chimney connectors regularly.
17 - In the event of a chimney fire, shut all draft controls and blower off and call your fire department
immediately. Alert everyone in the house. If flue is still burning vigorously, throw baking soda into
firebox or discharge a fire extinguisher into fire box. After the chimney fire is over, have a certified
chimney sweep complete a level 2 chimney inspection, before farther use of your chimney.
18 - With new steel there is a small amount of oil or dirt on the metal. You may smell an odor. This is
normal during the first operation. You may want to assemble the furnace out of doors and build a
small fire in it to "BURN OFF" this dirt and oil before installing unit.
19 - Equip your home with fire extinguishers, carbon monoxide and smoke detectors.
20 - Do not burn garbage, gasoline or any other flammable liquids in this furnace.
21 - Do not burn furnace over 600
Anthra-Max Annual Maintenance - After every burn season
1 - Clean out firebox and ash pan area after each heating season.
2 - Replace any cracked or broken firebrick-very important!
If this is not followed your stove is at risk for warping and may void your warranty.
3 - Take out coal hopper, remove baffle insulation and reburn baffles. Clean them with vacuum
cleaner or blow gun. Once cleaned everything can be reinstalled back into stove. Before
reinstalling, clean fly ash from secondary baffle at inside back of stove.
4 - Check grates and shaker handle for wear or warping and replace if necessary. Check for any
loose hardware on doors, door latches and shaker handle, tighten or replace as needed. Check
all gaskets on window glass, hopper, fire and ash doors for deterioration or tears, replace where
necessary. Also check seal of doors by closing doors on a piece of paper. If you can move the
piece of paper between door frame and gasket, replace door gasket.
5 - Clean inside of single wall chimney connectors and chimney at least once annually (in Spring). For
longer life of your single wall chimney connectors, disconnect from stove, oil inside with vegetable
oil and store in attic during summer month.

Chimney Requirements

The minimum height of a chimney system for the D.S.
Stove is 20 feet. The chimney must exceed the roof of a
house at a minimum of 3 feet at any point of exit. In a pitched
roof installation the chimney must be 2 feet higher than any-
thing within a 10 foot radius of the chimney. It is important to
have a chimney draft of 0.06 water column. It is required to
abide by the manufacturer's instructions on Class A chimneys
as well as local building codes. It is not recommended to build
a chimney on an addition that is lower than the main part of
your house. Do Not extend the single wall chimney con-
nector past the inside of a masonry chimney liner. Never
connect this unit to a chimney serving another appliance.
Should you have a problem with inadequate draft you should see page 11.
F or warranty will be void!
o
3
10 feet