Manual for AnthraMax.qxp_Manual for Circulator 5/19/18 11:38 AM Page 8

Optional Blower Installation

Use snap disc provided with blower. This will
prevent blower from running if unit is cold. You
should not run blower at start up until stove
has reached its desired temperature. This is
to allow regulator to reach its desired
temperature before blower is turned on.
Trouble Shooting
Problem 1 - Inadequate heat being delivered to your home,
Solution:
- Check home insulation – is it adequate?
- You may have poor circulation. For example, If your stove is in the basement and it is
warmer there than the first floor, put in a few floor vents to help move the hot air to where
it's needed. (see page 4)
- If you have hot air regulator set at High and stove does not heat properly, shorten chain
one or more notches (see page 6). DO NOT exceed 600 o F on top of stove.
Overheating will damage stove.
- Do you have a good draft of 0.06 water column.
- If not, check and clean chimney and single wall chimney connectors
Problem 2 - Stove burns too hot
- Turn Hot Air Regulator to low. If it does not burn low enough, lengthen chain one or more
notches at draft intake (see page 6)
- Check gasket in Bottom Ash Door (replace if needed). Ash door must be sealed.
Problem 3 - Poor Draft
- Check and clean chimney and single wall chimney connectors
- Check chimney draft – there should be 0.06 inches of water column. This service is
provided by a certified chimney sweep.
- Open manual damper if you have one
- If you have barometric damper? Is it installed properly? Read the instructions.
- Check ash pit. If it is too full - empty it.
- there may be a cracked flue liner. If so you need to reline chimney before further use
of stove.
- Make sure no other fuel burning devices are connected to the chimney impairing the draft.
- Make sure all of chimney mortar connections are airtight.
- Check chimney for possible down draft caused by taller surrounding trees or objects.
- Make sure clean-out door is closed tight if you have one
Problem 4 - Odor from first fire
- Uncured paints and oils will create an odor that can last a few hours. Odors can continue to
develop if you make hot fires until the paint cures.
Problem 5 - Coal Gas Explosions
- Oiled or wet coal could make matters worse. Coal gas explosions come from lack of
oxygen, or lack of secondary air. Set air wash on high.
Bend tab to 90
to protect regulator
Bend tabs to 60
8
Back of Unit
o
o