Ansell ARGBC/350 Instrukcje instalacji

Przeglądaj online lub pobierz pdf Instrukcje instalacji dla Sprzęt oświetleniowy Ansell ARGBC/350. Ansell ARGBC/350 2 stron. 350ma led rgb controller

General Installation Instructions
These instructions should be read carefully prior to any installation and retained after completion for further reference and maintenance.
Please give these instructions to the building owner/occupier after installation.
Important Safety
1.
Before installation, maintenance or lamp replacement, ensure that the mains supply to the luminaire is switched off and the circuit supply fuses are removed or
the circuit breaker is turned off.
2.
It is recommended that only a qualified electrical contractor carries out the installation of this luminaire and that the luminaire is installed in compliance with the
current edition of the IEE Wiring Regulations.
3.
The person carrying out the installation is to check and verify that the total load on the circuit, including that of this luminaire does not exceed the rating of the
circuit cable, fuse or circuit breaker.
4.
Where a luminaire incorporates discharge control gear (inductive load), the circuit capacity and ratings require careful sizing to avoid nuisance tripping of the
protective device used in the installation.
5.
Where applicable, careful consideration should be taken during installation to ensure that all fixings and/or suspensions are of a suitable size for the luminaire
being installed.
Ratings
1. All luminaires are manufactured & tested in compliance with the requirement contained within BS EN 60598 and are CE marked.
2. All luminaires that are of Class 1 construction and that are marked accordingly, MUST be earthed.
3. All luminaires are designed to operate at 230Volts AC -6%/+10% = 216Volts to 252Volts. Do not operate outside these voltages.
4. All luminaires are only suitable for applications within their rated Ingress Protection limits as stated.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Information – Required RGB Components (Sold Separately)
ATLED/RGB – Trio 9W Spotlight and / or AGWOLED/RGB – Gemini 9W Inground Uplight.
AD60W/48V 60W 48V LED Driver = 40W Max Operation.
Installation
Select a suitable mounting location to install the RGB luminaire. Care should be given to ensure adequate ventilation for luminaire. This luminaire is not suitable for high temperature
areas.
The RGB Controller should be used along with a suitable 48V LED Driver (Ansell part code AD60W/48V = 40W Max). Please see wiring diagram below.
The ARGBC/350 will control a maximum of 40W of 350mA RGB products (ATLED/RGB x 4, AGWOLED/RGB x 4).
Please refer to instructions supplied with the RGB luminaires for installation and connections to the ARGBC/350.
Please note that the ARGBC/350 has an IP rating of IP20, so if installed externally the controller must be installed within an IP rated enclosure suited to the application in accordance to
th
the current 17
edition wiring regulations BS EN 7671.
Optional expansion can be achieved for larger installations using the ARGBC/R/350 repeater. See diagram below for details. Max Distance from Controller to Repeater = 1000M
On/ Off = Switches the controller on / off. Note – Any button can start the controller at off status.
Pause = Pause current operation.
Mode + / Mode - = Press this button to select the next mode. Please refer to Table 1
Speed + / Speed - = Increase or decrease speed of program (Press either button for 3 seconds to restore to default).
Brt + / Brt - = Increase or decrease brightness of output (Press either button for 3 seconds to restore to default).
DIY Modes (Controller) 1-4 = Pre either button for 3 seconds (LED flashes for confirmation). Saves the current program. Just press button again to re-call saved program.
DIY Modes (Remote) 1-8 = Pre either button for 3 seconds (LED flashes for confirmation). Saves the current program. Just press button again to re-call saved program.
Play = Cycle the 4 pre-set modes.
Play + = Cycle the 8 pre-set modes in the remote.
RGB = Press either R, G or B buttons to change brightness of the RGB LED.
Table 1
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Maintenance:
1. This luminaire contains no serviceable parts.
Disposal of Electronic Equipment WEEE Directive 2002/96/EC
This product falls within the scope of the Waste Electrical & Electronic Equipment Directive
(WEEE), which means the product should not be disposed of as normal household waste.
Ensure that this luminaire and lamp is disposed of in accordance with the WEEE Directive.
Contact a local Council Waste Dept. Local Amenity Site, or the Environment Agency for
further information. RoHS - All components and materials used in this product are RoHS
2002/95/EC compliant.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
www.anselluk.com
Description – 350mA LED RGB Controller
Installation Instructions
®
Luminaire Code(s) –
IP20
ARGBC/350
R – Red, G – Green, B – Blue, + - Black
Issue Date: td 20120621