6.3 Setting the vertical angle

1. IMPORTANT: to ensure proper detector performance, set the vertical angle so that the base of the product is parallel to the ground.
2. Determine the required detection distance and mask the lens using the appropriate strips.
3. Perform a detection test making sure that the 2 beams (1 and 2) are interrupted one after the other.
Beam 1
Beam 2
If the detection distance
is shorter than required,
increase the vertical
angle.
0 degrees is the right setting for an installation
height of 3 m as long as the wall is perpendicular
to the ground over the entire detection length
4. Tighten the locking screw.
12 m
3 m
If the detection distance
is in line with the
requirement, there is no
need to change the angle.
Adjustment: 1 click corresponds
to a 2.5 degree upward adjustment
IMPORTANT: the detection zone can be adjusted using the
masking strips without changing the angle. The base of the
detector should be parallel to the ground to ensure the quoted
detection range is achieved. Minor rangte adjustments can be
effected by adjusting the vertical angle as follows.
If the detection
distance is greater
than required, reduce
the vertical angle.
5° (2 clicks)
10° (4 clicks)
81