DSC LCD5500Z Instrukcja instalacji
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Panel sterowania DSC LCD5500Z. DSC LCD5500Z 8 stron.
Również dla DSC LCD5500Z: Skrócona instrukcja obsługi (4 strony)
LCD5500Z / PKP-LCD
v3.x Installation Instructions
Introduction
The LCD5500Z / PKP-LCD keypad displays system
status using an LCD screen. The keypad can be
used on PowerSeries security systems with up to 64
zones.
Specifications
• Connects to control panel via 4-wire Keybus
• One keypad zone input
• Current draw: 45mA (standby); 85mA (max)
• Five programmable function keys
• Ready (green), Armed (red) and Trouble (yellow)
status lights
Installation
Unpacking
The LCD5500Z / PKP-LCD package includes the
following parts:
• One LCD5500Z / PKP-LCD keypad
• Four mounting screws
• One set of Fire, Auxiliary and Panic key labels
Mounting
You should mount the keypad where it is accessible
to designated points of entry and exit. Once you
have selected a dry and secure location, perform the
following steps to mount the keypad:
1. For the PKP-LCD, remove the end-cap located at
the bottom of the keypad. This can be done by gently
inserting a small flathead screwdriver into the groove
separating the end-cap and the rest of the keypad.
2. Remove the keypad backplate by removing the
two screws located at the base of the unit.
3. Secure the keypad backplate to the wall in the
desired location. Use the screws provided.
4. Before attaching the keypad to its backplate,
complete the keypad wiring as described in the
next section.
Wiring
1. Before beginning to wire the unit, ensure that all
power (AC transformer and battery) is
disconnected from the control panel.
2. Connect the four Keybus wires from the control
panel (red, black, yellow and green) to the keypad
terminals (R B Y G). Consult the diagram below:
WARNING: Please refer to the System Installation
Manual for information on limitations regarding
product use and function and information on the
limitations as to liability of the manufacturer.
TM