OWNER'S MANUAL
REMOTE CONTROL VIA THE MENU UTC
If you have a UTC DVR you can control the camera menu
remotely via UTC protocol. The UTC control does not
require additional cables as controls passing along the
video cable.
For how to activate the UTC Command check DVR
manual.
REMOTE CONTROL VIA THE MENU RS485
The camera is equipped with an RS485 port that can be
used to remotely control the brightness of the illuminators
and the OSD menu. This way you can adjust all the
parameters remotely.
To send RS485 commands it takes a PTZ console or DVR
with RS485 port.
The settings to be set to communicate with the camera
are fixed:
Pelco D Protocol
SPEED '9600 bps
ADDRESS 1
The commands are sent to the camera by calling the
following presets
RE-BCC8FD camera license plate
DSE srl - Digital Surveillance Equipment - WWW.DSE.EU
CALL PRESET + 95 - Opens the OSD menu of the
camera
PROBLEMS AND SOLUTIONS
IR LED does not light up at night - Verify that there is
a source of light that illuminates the sensor on the rear of
the camera.
Glare on the plate - Avoid directly oriented towards the
camera lights (min 30 °).
The plate is moved- Check goal setting. Reduce the
shutter speed to 1/1000 or 1/1500
Targa too bright or dark at night - Adjust the power
of the LEDs according to the shooting distance
The power of LEDs varies after a reset - Confirm the
IR power settings to save it after adjustment
The plate is too small and you can not read -
Increase the zoom lens to focus the shot.
No video - Make sure your DVR supports the AHD 1080P
format.