DSE 8660 Instrukcje instalacji - Strona 2

Przeglądaj online lub pobierz pdf Instrukcje instalacji dla Kontroler DSE 8660. DSE 8660 2 stron.

DSE 8660 Instrukcje instalacji
ADJUSTABLE PARAMETERS
Front Panel Configuration Editor
Section
Parameter as shown on display
Display
Contrast
Language
Current Date and Time
Timers
LCD Page Timer
Scroll Delay
Battery Under Voltage Warning
Delay
Battery Over Voltage Warning Delay 1m
Start Delay Off Load
Start Delay On Load
Start Delay Telemetry
Start Delay Mains Fail
Mains Transient Delay
Return Delay
Mains Transient Time
Mains
Under Voltage Trip
Over Voltage Trip
Under Frequency Trip
Over Frequency Trip
CT Primary
CT Secondary
Mains KW Rating
Mains KVar Rating
AC System
Bus
Start Delay On Load
Insufficient Capacity Delay
Battery Under Volts Warning
Battery Under Volts Warning Delay
Battery Under Volts Warning
Battery Over Volts Warning
Battery Over Volts Warning Delay
Battery Over Volts Warning
Load Level For More Sets
Load Level For Less Sets
Load Ramp Rate
Scheduler
Schedule
Schedule Loading On Load
Schedule Period
Schedule Time & Date Selection
(1-16)
Factory Settings
53%
English, others.
hh:mm
5m
2s s s s
1m
5s
5s
5s
5s
2s
30s
0.7s
184V
276V
45Hz
55Hz
600A
5A
345kW
258kW
3 Phase 4 Wire
5s
1s
Active
1m
10V
Active
1m
30V
80%
70%
3%/s
Inactive
Inactive (Only Available
When Scheduler Is Active)
Weekly (Only Available
When Scheduler Is Active)
Press
to begin editing
then
or
when
selecting the different
parameters in the
scheduler.
ACCESSING THE 'RUNNING' CONFIGURATION EDITOR
The 'running' editor can be entered while the engine is running. All protections remain active if the
engine is running while the running editor is entered.
Press and hold the
button to enter the running editor.
ADJUSTABLE PARAMETERS (Running editor)
Enter the editor as described above.
Press the up
or down
buttons to cycle to the section you wish to view/change.
To Edit the parameter press the
button to enter edit mode. The parameter begins to flash to
indicate that you are editing the value.
Press the up
or down
buttons to change the parameter to the required value.
Press the
button to save the value. The parameter ceases flashing to indicate that it has been
saved.
To exit the editor at any time , press and hold the
Running Editor
Section Parameter as shown on display
Display
Contrast
Language
Load parallel power
Load Power factor
Commissioning screens
Mains decoupling test mode (Stop mode only)
)
Voltage adjust (manual mode only engine running
breaker open)
Frequency adjust (manual mode only engine running
breaker open)
DIMENSIONS
240.0mm x 181.1mm x 41.7mm
(9.4" x 7.1" x 1.6")
button.
Factory Settings
53%
English
30%
63%
Inactive
Inactive
0V L-N
0 Hz
PANEL CUTOUT
:
220mm x 160mm
(8.7" x 6.3")