Function
System control function
code
54-59
Reserved
60
SMS run on load signal (88xx/84xx only) - sent by the display
processor to the control processor to signal when an SMS
command to run the generator on load has been received
61
SMS run off load signal (88xx/84xx only) - sent by the display
processor to the control processor to signal when an SMS
command to run the generator off load has been received
62
SMS request auto mode (88xx/84xx only) - sent by the display
processor to the control processor to signal when an SMS
command to change to auto mode has been received
63
SMS request stop mode (88xx/84xx only) - sent by the display
processor to the control processor to signal when an SMS
command to change to stop mode has been received
64
SMS request clear run mode (88xx/84xx only) - sent by the
display processor to the control processor to signal when an SMS
command to clear the run request has been received
65
SMS run in island mode signal (8820/8860/8420 only) - sent by
the display processor to the control processor to signal when an
SMS command to run the generator in island mode has been
received
66
Reset battery maintenance alarm 1
67
Reset battery maintenance alarm 2
68
Reset battery maintenance alarm 3
69
Auto DPF regeneration inhibit on
70
Auto DPF regeneration inhibit off
71
Start manual DPF regeneration
72
Battery Charger Boost Mode
73
Battery Charger Stop Charging
74
Battery Charger Battery Test
75
Battery Charger Select Alternative Charging Voltage
76
Select Off Mode
77
Throttle Down
78
Throttle Up
79
Wake ECU
80
Lamp Test
81
Battery Charger Auxiliary Boost Mode
82
Battery Charger Auxiliary Stop Charging
83
Battery Charger Auxiliary Battery Test
84
Battery Charger Auxiliary Select Alternative Charging Voltage
85-65535
Reserved
056-051 Gencomm Control Keys Issue 3 – A.D.Manton
System control
Ones compliment
key
of control key
(decimal)
(65535-control
35760
35761
35762
35763
35764
35765
35766
35767
35768
35769
35770
35771
35772
35773
35774
35775
35776
35777
35778
35779
35780
35781
35782
35783
35784
key)
29775
29774
29773
29772
29771
29770
29769
29768
29767
29766
29765
29764
29763
29762
29761
29760
29759
29758
29757
29756
29755
29754
29753
29752
29751