2.00 Installer Programming

Programming can only be done, when the unit is in off mode. This is indicated by the PWR LED
extinguished . When 1st connecting power to the AD1200, the PWR LED will come on indicating
unit in standby mode.
The dialler will exit installer programming if no data entering after 2 minutes
To enter off mode, enter in the User Code.
Press:
1
1
1
If the PWR LED is on after entering user code, re-enter the user code again.
Acceptance of programming is given by 6 short beeps from the buzzer., error tone is indicted by a
long beep.
2.01 Entering Installer Programming Code
Press:
7
7
7
D
ot on LED display starts blinking, you are now in installer programming mode.

2.02 Programming New Installer Code

Press:
CODE
0

2.03 Recall New Installer Code

Press:
READ
CODE

2.04 Burn In Installer Code

Press: CODE
9

2.05 Setting Pulse or Tone Dialling

The factory default setting is tone, if set to pulse when dialing the telephone numbers the dial LED
will flash. To enabled pulse or tone dialing:
Press:
PROG
0

2.06 Operating Through PABX

Press:
PROG
0
If the AD1200 has to call through a PABX system. Program in this location the telephone number
which obtains an outside line. The dialer will wait for a outside line dial tone, before dialing the
programmed telephone numbers. For # press VOICE and for * press CODE

2.07 Deleting PABX Line Extension Number

Press:
PROG
0
AD1200 Installer Manual, Rev. 19.06.2013
1
Press: ENTER
7
Press: ENTER
Enter new 4 digit code
?
0
After using this command the Installer Code can not be modified!
2
Press:
0
Pulse or
3
Press:
?
outside line number
3
ENTER
4
PWR LED extinguished.
?
?
?
1
Tone