SENSITIVITY ADJUSTMENT
It is possible to adjust the detection sensitivity by adjusting the interruption time adjustment volume.
When the unit is mounted on a wall, the interruption time can be set longer because the intruder cannot move quickly. This way,
it is possible to prevent an erroneous operation by a bird, small animal, paper and other object that flies in.
Adjust the sensitivity with the moving speed of a possible intruder taken into consideration. Also, be sure to check the unit for
operation after adjustment.
9
OPTICAL AXIS ALIGNMENT
There are two ways for optical axis alignment, by using a level meter or a tester.
1. Alignment using a level meter
(1) Rough adjustment
While looking into the scope located in the center of the
lens 10 to 15cm away from it, turn the turntable and hori-
zontal adjustment screw for adjustment in the horizontal
direction and the vertical adjustment screw for adjust-
ment in the vertical direction until the detector on the other
side is in the center of the scope as shown in the scope
view shown below.
Turntable
Horizontal
adjustment
screw
(2) Fine adjustment
Check the level meter of the receiver.
When the square marked level lamp in the table on the
label is turned off, it means alignment is completed.
If the lamp remains on, adjust the horizontal and vertical
adjustment screws of the transmitter and receiver until
the square marked level lamp turns off.
1
2
Running
Jogging
(4.5m/sec)
(2.2m/sec)
50msec
100msec
Scope view
Vertical
adjustment
screw
6
3
4
Fast walking
Normal walking
(1.1m/sec)
(0.75m/sec)
200msec
300msec
2. Alignment using a tester
(1) Rough adjustment
While looking into the scope located in the center of the
lens 10 to 15cm away from it, turn the turntable and hori-
zontal adjustment screw for adjustment in the horizontal
direction and the vertical adjustment screw for adjust-
ment in the vertical direction until the other detector is in
the center of the scope as shown in the scope view shown
below.
Turntable
Horizontal
adjustment
screw
(2) Fine adjustment
Insert the tester stick into the tester hole in the receiver
to check the tester voltage.
If the measured value is 3V
or more, adjustment is
completed.
If it is less than 3V, adjust
the horizontal and vertical
adjustment screws of the
transmitter and receiver
until 3V or more voltage is
obtained.
5
6
Slow walking
Slow moving
(0.55m/sec)
(0.45m/sec)
400msec
500msec
Scope view
Vertical
adjustment
screw
Tester hole