second to restore the original output state of all zones.
Note: All are two-color lights except for the LINE CONTROL and Long Press ALL SET indicators.
23—Zone Output Volume Control
Note: There are 6 gears in total.
24—Zone ON/OFF Button
a. When the output indicator light of the current zone is off, press this button to turn on the output of the zone.
b. When the output indicator light of the current zone is on, press this button to turn off the output of the zone.
25—System Host / Expansion Host AC Power Indicator
Green - Indicates that the current system host / expansion host AC power supply is normal.
Yellow - Indicates that the current system host / expansion host AC power supply is faulty.
Yellow 1-Second Strobe - The AC power fuse is faulty.
26—System Host / Expansion Host DC24V Backup Power Indicator
Green - Indicates that the backup power supply of the current system host / expansion host is normal.
Off - Indicates that the backup power supply of the current system host / expansion host is not configured.
Yellow - Indicates that the backup power supply of the current system host / expansion host is faulty.
Yellow 1-Second Strobe - The DC power fuse is faulty.
Note: The host backup power supply is configured in the system control software interface.
27—System Status Indicator
Yellow 1-Second Strobe - Amplifier failure, power failure, EMC MIC failure, open-circuit/short-circuit or ground
fault of any zone, CAN bus communication failure, SD card failure (detect whether the SD card is inserted or not
and whether some special files are missing), whether the EVAC file exists or not, and whether the ALERT file exists
or not are all faults. If no ACK is received, this indicator will remain flashing. The host buzzer frequency refers to
that of the host PAVA9500.
Normally Yellow: If ACK is received for a system fault, this indicator light will light up normally yellow.
Off - Each module is working normally or the master detection switch is not turned on.
Note: If the master detection switch of the system is turned off, this indicator light will go out, but it does not mean
that all modules are normal.
28—Remote Pager Connection Status Indicator
Green - Indicates that a pager is currently working.
Off - Indicates that the system pager is connected normally.
Yellow - Indicates that the pager is not logically or physically connected to the system host.
Note: Please configure according to the actual number, address and type.
29—Emergency Microphone Status Indicator
Green - Indicates that the microphone is working.
Off - Indicates that the current microphone is normal and not working.
Yellow - Indicates that the microphone is faulty.
30—System Host / Expansion Host Connection Status Indicator
Green - Indicates that the current device is connected normally.
Off - Indicates that the current expansion host is not logically or physically connected to the host PAVA9500.
a. Host: It is not connected to the software PAVA9000 and connected to the expansion host normally.
b. Expansion Host: It is not logically or physically connected to the system host.
Yellow - Indicates that the current host is not logically or physically connected to the expansion host.
31—System Equipment LED Test (Mainly test the LEDs on the panel of the host and expansion host as well as remote
pager)
Note: If the system is configured with an expansion host and remote pager, press this button to enter the LED test
mode synchronously, and the LEDs on the panel will light up sequentially from red to green to yellow.
Rear Panel
/