the mounting lugs in the rack.
Step 3
Shift out the device from rack, disassembling
ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power
on.
Power OFF operation: First, remove the power plug,
then remove the wiring section of terminal block.
Please pay attention to the above operation sequence.
Please be aware of the power input range supported
by the device before powering on. Use the
recommended voltage of the device to avoid device
damage.
【Power Supply Connection】
with 90~264VAC), and adopts 7-pin 5.08mm pitch terminals,
and the power supply occupies the right 5 pins. This power
supply supports anti-reverse connection.
【Relay Connection】
pitch terminal blocks, and the relay occupies 2 bits on the
left. They are open circuit in normal non alarm state, closed
when any alarm information occurs. The relay can externally
connect to alarm lights or alarm buzzer or other switching
value collecting device in order to timely notify operators
when the alarm occurs.
Note:
Relay terminals are reserved and not open yet.
【Console Port Connection】
The device provides 1 program debugging port based on
RS-232 serial port which can conduct device CLI command
management after connecting to PC. The interface adopts
RJ45 port, the RJ45 pin definition is as follows:
Pin No.
Pin Definition
【Checking LED Indicator】
The series product provides LED indicators to monitor the
device working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
P1
The device supports 2
12~48VDC
power
inputs
(compatible
P2
RUN
The device supports 1
relay
alarm
information
output,
using 7-pin 5.08mm
ALM
Link
(G1-G24,
X1-X4)
2
3
5
TXD
RXD
GND
Indicate
Description
Power supply is connected
ON
and running normally
Power supply is disconnected
OFF
or running abnormally
PWR is connected and
ON
running normally
Power supply is disconnected
OFF
or running abnormally
The system is running
Blinking
normally
The system is not running or
OFF
running abnormally
The system is running
ON
abnormally
Power supply or port link has
ON
alarm
Power supply, port link without
OFF
alarm
Port has established valid
ON
network connection
Port is in a network
Blinking
communication status
LED
Indicate
Description
Port hasn't established valid
OFF
network connection.
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
Step 1
Configure the IP addresses of computer and the
device to the same network segment, and the
network
between
them
accessed.
Step 2
Enter device's IP address in the address bar of
the computer browser.
Step 3
Enter device's username and password in the
login window as shown below.
Step 4
Click "Login" button to login to the WEB interface
of the device.
Note:
The
default
IP
address
"192.168.1.254".
The default user name of the device is "admin", no
password.
can
be
mutually
of
the
device
is