SET-UP & CONFIGURATION
3.
Set-up and Configuration
IMPORTANT: Do not connect the DVISn RF output signal to a network before reading these instructions and ensuring that the
RF level of the output signal is set appropriately (see section 3.3, RF Output Connections).
3.1
Connect PC to DVISn
Set-up of the DVISn unit requires a laptop or desktop PC running any OS supporting a web browser system and with available
Ethernet connection (called the "management computer" in the following procedures). Network parameters of the management
computer must be set appropriately for access to the DVISn remote management interface. The following procedures assume
the use of Windows
a different OS or network address are used, adjust the procedures to suit.
1.
Set the management computer's Ethernet interface to a static IP address on the 192.168.0.x subnet.
a) From the Control Panel, open Network Connections and select the connection associated with the Ethernet
adapter to be used for connecting to the DVISn (e.g., Local Area Connection).
b) Right click on the connection and select Properties.
c)
Select Internet Protocol (TCP/IP) and click Properties.
d) Click the selection box beside Use the following IP address to enter a check mark in the box.
e) In the IP address field, enter 192.168.0.x (where x represents any number from 1-253 except 23).
f)
In the Subnet mask field enter 255.255.255.0.
g) Click OK and then OK again in the previous window.
2.
Connect the management computer's Ethernet adapter to the DVISn Ethernet port using a CAT5e crossover cable
(supplied with the unit).
3.
Connect the video source and audio source (if required), and turn these external sources on.
4.
Connect the DVISn to the main power supply and switch the unit on. The green LED labelled POWER lights to
indicate that the unit is on.
5.
Allow the unit to boot for 90 seconds. While the unit is booting, the cooling fan may start to work, stop after few
seconds, then start to work again.
6.
On the management computer, open a web browser and enter http://192.168.0.23 in the address field.