3onedata IES6300 Series Instrukcja szybkiej instalacji - Strona 4

Przeglądaj online lub pobierz pdf Instrukcja szybkiej instalacji dla Przełącznik 3onedata IES6300 Series. 3onedata IES6300 Series 5 stron. Managed industrial ethernet switch
Również dla 3onedata IES6300 Series: Instrukcja szybkiej instalacji (4 strony)

3onedata IES6300 Series Instrukcja szybkiej instalacji
Provide 4 pins DIP switch for function
settings, where "ON" is enable valid
terminal.
The device needs to be powered on
again to change the status of DIP switch.
DIP switches definition as follows:
DIP
Definition
Operation
1
Restore
Set the DIP switch to ON, the
factory
device will root automatically and
defaults
restore to factory settings, then turn
off the DIP switch.
2
Reserved
-
3
Reserved
-
4
Reserved
-
【I/O Port Connection】
Model 1, Model 2, Model 3, Model 4,
Model 9, Model 10, Model 11,
Model 12, Model 17, Model 18,
Model 21, Model 22, Model 23,
Model 24, Model 25, Model 31 and Model 32 of this device
provide 8-pin 3.81mm pitch terminal blocks and I/O port with 2
inputs and 2 outputs. This device can detect and send I/O
input status to management software, operators can set the
conditions of alarm status via management software. When
the I/O input status meets the set alarm conditions, the I/O
output alarm would be triggered. The pin definitions of I/O port
are shown as follows:
I/O port
PIN
DI data signal input 1
DI1+, DI1-
DI data signal input 2
DI2+, DI2-
DO data signal output 1
DO1+, DO1-
DO data signal output 2
DO2+, DO2-

【Console Port Connection】

The device provides 1 channel procedure debugging port
based on RS232 serial port, and can conduct device CLI
command line management after connected to PC. The
interface adopts RJ45 port, the RJ45 pin definition as follows:
Pin No.
Definition
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working
status
troubleshooting; the function of each LED is described in the
table as below:
LED
P1/P2/PWR
ALM
RUN
Link/Act
(1-4/8)
Definition
I/O signal input
PoE(1-4/8)
I/O relay output
DO(1-2)
DI(1-2)
2
3
5
TXD
RXD
GND
with
a
comprehensive
simplified
Indicate
Description
PWR is connected and running
ON
normally
PWR
is
disconnected
OFF
running abnormally
ON
Power supply, port link alarm
Power supply, port link without
OFF
alarm
The device is powered on or the
ON
device is abnormal.
The device is powered off or the
OFF
device is abnormal.
Blinking 1 time per second,
Blinking
system is running well.
The
Ethernet
interface
ON
established an active network
connection.
The Ethernet interface is in a
Blinking
network activity state.
Ethernet
port
has
OFF
established
valid
network
connection
ON
POE port is powering other
devices normally
OFF
POE is disabled or disconnected
ON
I/O has output alarm information
OFF
I/O
has
no
output
information
ON
I/O has input information
OFF
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
Step 1
Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed
Step 2
Enter device's IP address in the address bar of the
computer browser.
and
Step 3
Enter device's user name and password in the
login window as shown below.
has
not
Step 4
Click "OK" button to login to the WEB interface of
the device.
Notes:
The default IP address of the device is "192.168.1.254".
The default user name and password of the device is
"admin".
alarm
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
I/O has no input information