Aube Technologies CT230-120GA Instrukcje instalacji - Strona 2

Przeglądaj online lub pobierz pdf Instrukcje instalacji dla Termostat Aube Technologies CT230-120GA. Aube Technologies CT230-120GA 2 stron. Aube technologies master thermostats and slave units installation instructions

3.3 Master Thermostat - Installation and Wiring
WARNING: Make sure all slave units are in STANDBY mode.
•Required
parts:
TH113-A/F/AF (12VDC),
TH114-A/F/AF (12VDC),
TH115-A/F/AF (12VDC) or
TH116-A/F/AF (12VDC)
• Location: anywhere easily accessible to users.
Temperature control: AF (ambient with floor limit) / A (ambient)
Install the master thermostat in the controlled area.
Choose a location about 5 ft. above the floor in an area where the tempera-
ture is stable.
Avoid locations where there are air drafts (top of staircase, air outlet), dead air
spots (behind a door), direct sunlight or concealed chimneys or stove pipes.
Temperature control: F (floor)
Can be installed anywhere.
Wire the 12 VDC base to the nearest slave unit.
The floor sensor must be installed in an area where average temperature can be
read. The cable must follow the wall down to the floor and must not cross any
heater wires or be directly on or adjacent to a heating wire.
For maximum performance, the sensor probe should be centered between the
wires in the mat (max. 80°C).
Push the excess wire into the wall, secure the base using the provided screws
and wall anchors, and install the TH11x thermostat onto the base.
Once the thermostat is installed, return power to heating system and switch all
slave units and the master thermostat to ON.
3.4 Slave Units - GFCI Test
We recommend you test the GFCI immediately after installing the thermostat, and
once a month thereafter to ensure it is operating properly.
If the test warning light comes ON during normal operation, cut power to heating
system from the main power panel and verify the installation.
Slide the protective door upwards and make sure the switch is ON.
Press TEST.
The test is successful if the TEST warning light is ON and power is cut off.
If the test fails (first installation test):
a. Verify installation
b. Check the load wires
c. Once you've identified the problem, run the GFCI test again
If the test fails (monthly maintenance):
a. Cut power to heating system from the main power panel and call customer
service
When the test is successful, reset the slave unit by switching from ON to
STANDBY then back to ON.
Repeat steps 1 to 3 for all slave units.
Technical Specifications
Temperature:
- Operation: 32°F to 122°F (0°C to 50°C)
- Storage: -4°F to 122°F (-20°C to 50°C)
TH113/TH114/TH115/TH116 (A/F/AF-12VDC)
Power supply
12 V from remote unit
Maximum
up to 10 slave units per
slave units
master thermostat
Wire gauge
20 AWG
Size (H • W • D)
4.63 x 2.7 x 0.61 in.
BASE
(117.5 x 68.3 x 15 mm)
NOTE:
Refer to the TH11x user guide for technical
specifications.
CT230-120GA/120GB/240GA/240GB
Supply
- PB112-120
1800 W @ 120 VAC
60 Hz, 15 A resistive
- PB112-240
3600 W @ 240 VAC
60 Hz, 15 A resistive
GFCI
GA=5 mA / GB=30 mA
Certification
c CSA us
Size (H • W • D)
4.63 x 2.7 x 1.45 in.
BASE
(117.5 x 68.3 x 37 mm)
Size (H • W • D)
4.67 x 2.74 x 0.67 in.
INTERFACE
(118.6 x 69.6 x 17 mm)
Warranty
Aube warrants this product, excluding battery, to be free
from defects in the workmanship or materials, under nor-
mal use and service, for a period of three (3) years from the
date of purchase by the consumer. If at any time during the
warranty period the product is determined to be defective
or malfunctions, Aube shall repair or replace it (at Aube's
option).
If the product is defective,
(i)
return it, with a bill of sale or other dated proof of pur-
chase, to the place from which you purchased it, or
(ii)
contact Aube. Aube will make the determination
whether the product should be returned, or whether
a replacement product can be sent to you.
This warranty does not cover removal or reinstallation
costs. This warranty shall not apply if it is shown by Aube
that the defect or malfunction was caused by damage
which occurred while the product was in the possession of
a consumer.
Aube's sole responsibility shall be to repair or replace the
product within the terms stated above. AUBE SHALL NOT
BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND,
INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING, DIRECTLY OR INDIRECTLY,
FROM ANY BREACH OF ANY WARRANTY, EXPRESS
OR IMPLIED, OR ANY OTHER FAILURE OF THIS PROD-
UCT. Some provinces, states or regions do not allow the
exclusion or limitation of incidental or consequential dam-
ages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY
AUBE MAKES ON THIS PRODUCT. THE DURATION OF
ANY IMPLIED WARRANTIES, INCLUDING THE WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE
THREE-YEAR DURATION OF THIS WARRANTY. Some
provinces, states or regions do not allow limitations on how
long an implied warranty lasts, so the above limitation may
not apply to you.
This warranty gives you specific legal rights, and you may
have other rights which vary from province, state or region
to another.
Service
For any questions regarding the product installation or
operation, contact us at:
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
For more information on our products, visit us at:
www.aubetech.com
400-230-000-D
2/7/07
2/2