DC device: Model I, Model II, Model IV, Model V
Model I, Model II, Model IV and Model V
provides 6-pin 5.08mm pitch power supply
terminal blocks and power supply occupies
the left 4 pins. It provides two independent
DC power supply systems, P1 and P2. The power input
supports 1 power supply alone or 2 power supply at the same
time; When two power supply input at the same time, it
supports redundant backup of power supply. If one power
supply fails, the device can still work normally without
interruption. Power supply supports anti-reverse connection,
which cannot power the device but won't damage it when it's
reversely connected. The definitions of power pin are shown
in the left figure, and the power supply input is as follows:
Model I, IV: 24/48VDC (12~55VDC).
Model II, V: 48VDC (PoE: 44~55VDC).
AC device: Model III, Model VI
Model III and VI provide 6-pin 5.08mm
pitch terminal blocks (the power supply
occupies the left 4 pins) and 1 AC power
supply system. The definitions of power pin are shown in the
left figure, and the power input range is 110/220VAC
(85~256VAC/DC).
【Relay Connection】
This series device provides 6-pin 5.08mm
pitch terminal blocks, RELAY occupies the
right 2 pins. Relay terminals are a set of
normally open contacts of the device alarm
relay. They are open circuit in the state of
normal non alarm, closed when any alarm information occurs.
For example, they are closed when powered off, and send out
alarm. The relay supports the output of DC power supply
alarm or network abnormality alarm. It can be connected to
alarm light or alarm buzzer or other switching value collecting
devices, which can timely inform operators when the alarm
occurs.
【I/O Port Connection】
This series device provides 8-pin 3.81mm pitch terminal
blocks and 2 DI and 2 DO. This device
can detect I/O input status, and operators
can set the conditions of alarm status.
When the I/O input status meets the set alarm conditions, the
I/O output alarm would be triggered. The pin definitions of I/ O
port are shown as follows:
PIN
Definition
DI1+, DI1-
DI digital signal input channel 1
DI2+, DI2-
DI digital signal input channel 2
DO1+, DO1-
DO digital signal output channel 1
DO2+, DO2-
DO digital signal output channel 2
【USB Interface】
This
series
of
devices
Type-A(Female) interface. The USB interface can be
connected to a USB flash drive to download logs and
configuration files, or upload configuration files. For specific
operations, please refer to the appendix of the user manual.
【DIP Switch Settings】
The series of devices provide 4-bits DIP switch
for function setting, where "ON" is enable valid
terminal. The definitions of DIP switch are as
follows:
DIP
Definition
Operation
1
Restore
Set the DIP switch to ON, the
Factory
device will root automatically
Settings
and restore to factory settings,
then turn off the DIP switch.
2-4
Reserved
—
【Console Port Connection】
The series of device provides 1 program
debugging port based on RS-232 serial port
which
can
conduct
management after connecting to PC. The interface adopts
RJ45 port, the RJ45 pin definition as follows:
Pin No.
2
3
Definition
TXD
RXD
【LED Digital Tube】
This series of device provides a 1 7-segment LED
digital tube to display the running status of the device,
which is convenient for maintenance and understanding of the
working status of the products. The corresponding status is
shown in the following table.
LED digital tube
status
provides
a
USB2.0
device
CLI
command
5
GND
Note
When the digital tube displays
the character "b", it means that
the switch is in the power-on
self-test state.
When the digital tube displays
the character "_", it means that
the switch starts to load the
applications.
When the digital tube displays
the numbers "9" to "0" in turn, it
means that all the applications
of the switch are successfully
loaded.
When the digital tube displays
the character "c", it means that
the switch is in normal working
state.
When the digital tube displays
characters "-","u", "o", "∀"and
"8", it indicates the percentage
of PoE power output by the
switch to the total PoE power.
The corresponding relationship
is as follows:
-:0~20%
u:21%~40%
o:41%~60%
∀:61%~80%
8:81%~100%
When the digital tube flashes
and displays the character "t",