1. Overview
This JSL-72 timer is specifically designed for controlling coffee grinder.
It can count from 0.01" to 99.99" or from 1" to 99'59". Counting direction
can be set by user(counting up or counting down). Accumulated time/
cups can be automatically stored in the timer and reset by user.
Operating function modes include single dose, double dose and
manual. Most function features can be activated by front key pad or
remote switch. However, manual function can only be accessed
through remote switch. Three different display modes can be
programmed. User can shift among single/double dose display mode,
total running time display mode, and total number of cups display
mode. Timer adjust function can be deactivated to prevent any
accidental change.
2. Specification
Timer range: 0.01" to 99.99". Or 1" to 99'59"
Timer mode: single dose, double dose, manual
Timer trigger: power on, front key pad, or remote switch
Timer accuracy: <1s/day.
Power supply: 90-260V AC or DC.
Power consumption: <2W
Relay output:7A@240VAC,10@120VAC and 24VDC
Relay life: 100,000 times.
Operating temperature: 0-60 °C.
Humidity: 0-95%RH
Panel cutout: 44.5x44.5mm
Outer dimension: 48x48x85 mm.
3. Front Panel
8
1
2
4
Figure1. Front panel
1. Time range indicators: M for minutes, S for seconds. Both will be
illuminated when the time base is M:S(Minutes : Seconds)
2. Timer indicators: T1 is illuminated for single dose, T2 is
illuminated for double dose.
3. OUT indicator: illuminated when relay is on; turns off when relay
is off.
4. SET key. When timer is not running, in single/double dose
display mode, press it will shift between single dose time (T1) and
double dose time (T2)(see section 5.1 for details); press and hold it
for 3 seconds will shift between single/double dose display mode
and total running time/cups display mode(see section 5.1 for
details); press and hold it for 5 seconds will enter the parameter
programming menu(see section 5.2 for details).
2012.11
JSL-72 Timer for Coffee Grinder
3
5
6
7
Version 1.2
5. Down key: When timer is not running, in single/double dose display
mode, press it will lower the time setting value; in total running time/
cups display mode, hold it for 4 seconds will reset the value.
When timer is running, in either display mode, press it will stop the
timer. In programming mode, press it will go to the next programming
value.
6. Up key: When timer is not running, in single/double dose display
mode, press it will increase the time setting value. When timer is
running, press it will stop the timer. In programming mode, press it will
go to the previous programming value.
7. RST key: Reset key. When timer is not running, press it will activate
the timer. When timer is running, press it will stop the timer.
8. LED digital display. In single/double dose display mode, the top
displays the actual time; the bottom displays the set value. In total
running time/cups modes, the top displays the accumulated running
time/cups; the bottom displays tot/CuPS. In programming mode, the
top displays setting parameters; the bottom displays programming
value.
4. Terminal Assignment
Figure 2. Terminal assignment
Terminal functions when timer is running:
Manual(MAN),T2 (double dose time), T1(single dose time),
Common(COM).
Connecting MAN and COM: Timer starts running when they are
connected.
Connecting T2 and COM: Timer starts running for T2 when they are
disconnected .
Connecting T1 and COM: Timer starts running for T1 when they are
disconnected.
5. Programming
When timer is not running, press SET key for 5 seconds to enter the
programming menu. For each parameter setting, use up/down key to
select different programming values. Press SET key to confirm and
move on to next parameter. See figure 3 on next page for the
procedure. For the definition of each programming value, see
following section.