7. Troubleshooting
Please make sure the below has been checked before logging a service call.
NOISY
−
Check that the hood has correct size ducting (semi or rigid ideally).
−
Make sure there are no restrictions within the ducting outlet.
−
Make sure the minimum amount of 90 degree bends have been used.
−
Make sure the hood has been secured to the wall correctly as per instructions (fixing screws used to
secure).
−
Make sure cable hasn't been dropped into fan area.
−
Make sure back draught flaps have not been jammed semi closed against ducting.
−
In re-circulation mode make sure the flue vents/grilles are not covered.
POOR EXTRACTION
−
Check that the hood has correct size ducting (semi or rigid ideally).
−
Make sure there are no restrictions within the ducting outlet.
−
Make sure the minimum amount of 90 degree bends have been used.
−
Make sure back draught flaps have not been jammed semi closed against ducting.
−
Make sure ducting doesn't exceed recommended length run for the model installed.
−
Make sure customer is switching hood on 10 minutes before cooking and leaving on 10-15 minutes
after.
−
Advise customer to always reduce boiling water to simmer and use lids.
−
On recirculation mode it is more important to use lids on pots and pans to reduce steam/humidity in
room.