Ducati CTH44 Podręcznik - Strona 2
Przeglądaj online lub pobierz pdf Podręcznik dla Kontroler Ducati CTH44. Ducati CTH44 2 stron. Electronic board
D U C A T I
e l e c t r o n i c b o a r d
Connections and adjustments:
ATTENTION ! all settings have to be made with gate in closed position
ATTENTION ! in case of use use with power from photovoltaic panel use low consumption
photocells mod. 7120 only!
WARNING: it is mandatory to have the battery full charged before to power the electronic board. Charge
the battery before use. To charge the battery:
a) Use the supplied 12v transformer, connect it to the board ( yellow-black cables), connect the battery to
the borard first (respect polarity red cable= + positive / black or blue cable= -negative), connect a electric
wire min.0,75mmq to the terminals downstream of the transformer. Plug the electric wire to a power outlet.
b) Use a battery charger with charge control (ex. our optional battery charger MPBAT). respect polarity.
whait until the battery is fully charged ( green LED on MPBAT is steady on).
You must check the battery charge status by the control board:see herunder P2 procedure
CONNECTORS:
A/B antenna / sock
1/3 START contact NO full opening cycle
2 FTC photocells NC contact (to be connected to terminal 3 of low consumption photocell model RX 7120)
7/8 12V 10W max. blinking light
9 M1 actuator brown cable (note: M1 is the motore installed on the wing that opens first)
10 M1 actuator blue cable
11 M2 actuator brown cable
12 M2 actuator blue cable
13 + 12V solar panel positive
14 - 12V solar panel negative
15 + 2° solar panel positive ( the use of a 2° 12V solar panel is not mandatory)
16 - 2° solar panel negative
J8: +12 + power photocell positive
NEG - power photocell negative
Connectors (BAT+/-) to battery 12V
Warning: It is possible to power the board by 230V/110V (trough the transformer) instead of by solar
panel, but the battery ust be always keeped connected to the board.
The phase shift between gate wings is automatically set. M2 follows M1 in opening after about 3 sec. and
vice versa during closing.
Warning: Photocells bridge: between connectors 2/3.
Remove the bridge only when connecting the photocells.
Green LED =indicates the batery is fully charged
Red LED= indicates:-full cycle remotes control storage procedure/ the battery is out of charge/
blinking while the gate is open indicates the automatic closure working mode is settled.
Yellow LED=indicates:
-pedestian opening cycle remote control storage procedure
- battery is almost discharged
SWITCH 1 = switch it ON ( upper position) activates the ACOUSTIC and LED GUIDED PHOTOCELLS
ALIGNMENT SYSTEM
Connect the low consumption 7120 photocells to the electronic board. Put the photocell's alignment
switch (No. 1) in the up position. Try to align the protocell receiver to the photocell transmittent following
the acoustic and LED signals until you obtain a perfect alignment.
Long "BEEP" = CORRECT ALIGNEMENT = on the board the green LED is ON intermittent "BEEP-
BEEP-BEEP"= NOT ALIGNED = on the board red or yellow LED is ON. When the alignment procedure is
finished, put the alignment switch (1) back to the down position; otherwise the system will not operate.
32
C T H 4 4 "
f u l l s o l a r "
SWITCH 2 * = switch it ON ( upper position) activates the check for better solar panel positioning
REMEMBER: Perform this operation between noon and 2:00 p.m.
warning: switch 1 must be OFF ( lower position)
To find the better solar panel aligniment, check if the green LED on the control panel is on. Meanwhile, the
acoustic signal must emit a continuous BEEP to show that the solar panel is in a good position. If the acoustic
signal is intermittent and the red or yellow LED is on, it means that in this position exposure is inadequate for
charging. In this case, move the panel into other attachment positions until you find a good one. Solar panel
must always be positioned toward south. Once finisched the procedure, put the switch 1 OFF ( lower position)
PUSH BUTTONS P1; P2;
P1 = FULL CYCLE push button to store or cancel the radio transmitters codes on the electronic board.
This button is used to set complete opening cycles. Red LED visual indicator.
P1 + P2= PEDESTRIAN ACCESS push button to store or cancel the radio transmitters codes on the electronic
board. This button is used to set pedestrian opening cycles (partially activates only the door corresponding to
the motor M1 only ) to memorize a remote control push button to command the pedestian opening cycle:
press P1, hold P1 pressed, press P2. release P1 and P2, then press the remote control push button and hold it
pressed for about 4 seconds unil the red LED confirm the remote control push button has been stored.
P2 = BATTERY CHARGE STAUS CHECK the battery must be connected to the board. ( check the correct
polarity) Press and hold the P2 button to check the battery charge status, viewing the color of LED lights.
Make sure that green LEd is on, otherwise proceed to a full battery charge. If the battery is discharged, the sy-
stem goes into a protection state and will stop working. outcome of a new control tests. it will be necessary to
repeat the checking procedureuntil the the battery is checked to be fully charged ( green LED on) nthis way the
board will be restored.
Red LED on +Sound Buzzer = Low battery: the voltage is lower than 11,2V
yellow LED ON = Battery partially discharged: the voltage is between 12.4 and 12.9V
Green LED on = Battery charged: the voltage is greater than 12.9V.
HOW TO MEMORIZE/ DELETE REMOTE CONTROL CODE IN THE ELECTRONIC
BOARD ( see also remote control chapter)
Remote controls setting: to syncronize a remote control channel:
On the main board Press P1 to memorize a remote control Channel for compleete opening cycle.
Release P1.As the red LED turns on, push the selected radio remote control button. After the red LED blinks,
wait until the red LED turns off. Operation completed.Maximal storage capacity: 10 channels
To delete the stored channels press P1 for about 30 sec. until the red LED turns off.
All remote control codes will be delated.
POTENTIOMETERS
TIME
=
potentiometer to set the "step by step" mode of use or automatic closure
The potentiometer completely turned counterclockwise( position = 0 ) to use the standard setting "step by step"
mode of use. with this setting a pulse controls the opening and a second impulse closes the gate. By rotating
the potentiometer clockwise, you will set the automatic closure function.Turning the knob increases the time.
Maximum pause time = 100 seconds with potentiometer fully clockwise.
POWER M1:
POWER M2:
Turn the potentiometer clockwise to increase power and reduce obstacle detection sensitivity
Use on single wing gate: connect motor M1 only.
actuator M1 power /obstacle detection sensitivity adjustment
actuator M2 power /obstacle detection sensitivity adjustment