11. CTH29E circuit board

This circuit board is equipped with an amperometric safety system.
If an obstacle is detected, it stops movement.
It automatically stops movement in opening and closing directions (amperometric detection).
Connection for optional accessories: Photoelectric cells (Ref. SW7012); key-operated switch (Ref. SW5000).
Fig. 47
Aerial
RV1 = power
adjustment
Halogen bulb 20V
24W
Connection "M"
motor cables
red (left) blue (right)
Key-operated
switch
(optional)
P1 = storage/erasure of codes for the remote control or the
radio keypad (optional accessory)
LED = Red light. Power supply on and indicator for radio
code storage
RV1 = power adjustment trimmer
M = connection to motor
ST = start n.o.(contact normally open)
FTC = n.c. photoelectric cells (contact normally closed)
Com = common
+ = power 24V
IMPORTANT: if the optional photoelectric cells have
not been connected, the jumper connecting FTC and
COM must be in place. Otherwise, the automation
system will no longer close!
Hybrid receiver
-
+
+
0,5 mm
2
cable
0,5 mm
2
cable
START
Photoelectric
cell
transmitter
(optional)
ST FTC Com +
-
Photoelectric cell
TX (optional)
Fig. 48
transformer cables
RED
and BLACK
BLUE
motor
cable
RED
motor
cable
P1
LED
Connectio
n to
transforme
r red (24V)
and black
(0) cables
IMPORTANT: do not
remove the jumper
between the FTC
and COM terminals
except in the event of
connection of a pair
of photoelectric cells.
Otherwise, the
automation system
will no longer close.
230V
Alimentation
BLUE
motor
cable
RED
motor
cable
Page 15