Duct-O-Wire CAS-1RA-O Uzupełnienie - Strona 5
Przeglądaj online lub pobierz pdf Uzupełnienie dla Sprzęt oświetleniowy Duct-O-Wire CAS-1RA-O. Duct-O-Wire CAS-1RA-O 7 stron. Collision avoidance and reflector array kit
► This product incorporates IR Laser Protection Class 2; visible laser light.
► Do Not Stare Into The Laser Beam!
The Duct-O-Wire CAS-2L100 Two Event Laser Collision Avoidance Kit comes with (1) Laser Sensor Unit, (1)
Sensor Mounting Bracket and Hardware, (1) 10 Meter Data Cable, (1) DIN Mounted Power / Relay Module, (1)
Reflector Array with Mounting Hardware, Schematic Sheet and Warning Label.
Laser Class 2
Max Power 4.1 mW
Wave Length 650 mm
MAKE CERTAIN POWER SUPPLY IS DISCONNECTED BEFORE INSTALLING, REPAIR, OR MAKING
ADJUSTMENTS TO THIS DEVICE. THIS DEVICE IS TO BE INSTALLED BY QUALIFIED ELECTRICAL
PERSONNEL ONLY.
MOUNTING AND ALIGNMENT
1. Mount sensor and reflector using supplied bracket and hardware to suitable locations for
stability and proper alignment. Use 3 point alignment method to ensure the laser and
reflector are in a straight line, both horizontally and vertically true.
2. Connect the supplied data cable to the sensor and power / relay module per the drawing.
3. Attach the supplied Laser Warning Label in the immediate vicinity of the sensor unit.
4. Connect 110 VAC to the transformer per the schematic drawing.
5. A visible red light will be seen from the sensor to the reflector. Do Not Stare Into the
Laser Light.
SENSOR PROGRAMMING - FEET MODE (Use a pen or small blunt object for improved response)
NOTE: ALL BUTTON PRESSES MUST BE DONE WITHIN 15 SECONDS
1. Press and release the Mode/Enter button until EF is displayed. (multiple presses)
2. Press and release the SET button.
3. Press and release the Mode/Enter button until Uni is displayed. (6 button presses)
4. Press and hold the SET button until FEET is displayed, and release.
5. Press and release the Mode/Enter button once to confirm.
6. Wait 15 to 20 seconds and the unit will return to the "run" mode.
7. When sensor is in Run mode, distance to target is displayed in feet.
SENSOR PROGRAMMING – SET POINT 1 (first event distance)
NOTE: If the desired distance is passed, the counter will need to be advanced until the set
point is displayed again.
1. Press and release the Mode/Enter button until SP 1 is displayed. (2 presses)
2. Press and hold the SET button until the desired distance for the first event is displayed,
then release.
3. NOTE: Minimum distance is 1 meter (3.28 feet).
4. Press and release the Mode/Enter button once to confirm. The display will show SP 1.
5. Wait 15 to 20 seconds and the unit will return to the "run" mode.
Duct-O-Wire
CAS-2L100 Laser Collision Avoidance Kit
Installation and Operating Instructions
Effective June 1, 2012
Time Base 100 s
Compliance: 21 CFR PART 1040 EN60825-1:2003-10
ALL BUTTON PRESSES MUST BE DONE WITHIN 15 SECONDS
Pulse Duration 1.3 ms
.