Maintenance Unit
11
Element
7 - Oil mister
8 - Air filter and
water trap
10 - Pressure Regulator
UMBRUCH =
12
10
9
8
Function
-
With the regulating screw 5 set approx. 1 drop
for 10 work cycles. To fill interrupt the
compressed air feed and vent the system with
screw 9. Screw out screw 6 and fill
"Esso SP NK 10"-type oil up to the groove in
the glass.
-
Before the water level reaches the filter, screw
in screw 9 far enough to drain water.
Do not interrupt the compressed air supply.
-
To set to 6 bar pull the bushing 11 up
and turn appropriately.