Maintenance
Always conduct a routine inspection of your Surspider Rebar Tier
before and after using it:
•
Check for any cracks in the the casing
•
Check power switch is working correctly
•
Check all working functions of the tool, including making a wire ring,
wire length, wire cutting etc.
Clean the exterior of the tool using a mild detergent and water on a wet
rag after use.
Avoid storing or transporting the battery with metal objects to avoid short
circuiting.
If your gun gets damaged, please return it to your nearest branch of
Concrete Tool Importers for repair.
The warranty will be void if any repairs are carried out without
authorisation from Concrete Tool Importers in writing.
Your tool contains magnets which attract iron filings over time and need
checking and cleaning regularly.
Over time the head may get damaged through everyday wear and tear
to the point it is out of shape. If this happens the gun will not perform
correctly and may cause problems with not tying knots or wire breaking.
Check the diameter of the circles at the start of each job and adjust
accordingly.
If you have any problems with your Surspider Wire Tie Gun, check the
Trouble Shooting page in the first instance. If the problem remains
unresolved please contact Concrete Tool Importers on 0800 727 333
Your Surspider Wire Tie gun comes with a six month warranty for the
original purchaser from the date of purchase and covers manufacturing
Faults and the battery but not breakages or wear and tear.
17.
Concrete Tool Importers Ltd
0800 727 333
Trouble shooting
Problem
Possible Cause
Power indicator light red, battery is flat
Power indicator light is green, something else
Rebar tier not
has happened
working
Power indicator lights
Battery is not
are not flashing
connected correctly
Circuit fault
No or low wire in gun
Incorrect wire
Rebar tier is
working but
The locking button isn't press in
no wire is
coming out
The wire is blocked in the wire feed receiver
or tapered sleeve
Damaged wire
The right cutter has not reset and has blocked
tie lip
The wire outlet of the tying head is blocked
Battery level is low
Incorrect wire
Wire is not
tying tight
Wire length is too long
enough
Not enough tying power
Another reason
Incorrect wire
The wire length is to short, one less wrap than
Wire knots
needed
break
Tying power is too low
Another reason
One short beep when gun is turned on
One long beep, power indicator light is red
Buzzer
Three long beeps
sounds
Five long Beeps
Concrete Tool Importers Ltd
Solution
Replace and charge battery
Stop use, contact Concrete
Tool Importers 0800727333
Reinsert or replace battery
Stop use, contact Concrete
Tool Importers 0800727333
Install new roll of wire
Use the specified Surspider
wire only
Lock the wire roll by pressing
the lock button
Remove the wire and
reinstall the wire correctly
Remove wire, cut back to
good wire and reinstall.
Stop use, contact Concrete
Tool Importers 0800727333
Clean the wire outlet
Replace the battery
Use the specified Surspider
wire only
Adjust the wire length
Adjust the power
Stop use, contact Concrete
Tool Importers 0800727333
Use only the specified
Surspider wire
Adjust the wire length. Press
down on the lock button to
lock the wire roll.
Adjust the power
Stop using, send it to
Concrete Tool Importers
0800727333
Boot up, this is normal
Battery is flat, replace battery
Motor has a problem,
Contact Concrete Tool
Importers
Sleep mode, this is normal
0800 727 333