DIP-SWITCH - FUNCTIONS
BI-DIREZIONAL LEARNING
DIP1
Start the BI-DIRECTIONAL learning procedure to pair the siren with control
panel. Complete the procedure starting the same operation on control panel.
"BY DETECTION" LEARNING
Starts the "by detection" learning to pair the siren with control panels without
the BI-DIRECTIONAL function.
DIP2
The siren emits some times its TAMPER radio code (which must be learned int
radio zone memory of the panel) then listens for control panel radio code in
order to store it.
SUPERVISION
The siren sends a special "in life" radio code to inform the control panel of its
DIP3
correct working and presence.
The supervision code is transmitted after about 1 hour from last transmission.
The supervision enabled causes higher battery consumption.
ALARM BLOCK (COUNTER)
The siren sounds for max 5 alarms (each alarm sound lasts about 1 minute)
DIP4
during the same arming, then stops the sounds until the next arming.
It is possible to disable the alarm counting and make the siren sound without
limits.
LIGHT ALERTS AT ARMING AND DISARMING
The lamp LEDs light on at the arming and disarming of the system to give a
visual feedback to the user:
TOTAL ARMED
PARTIAL 1
DIP5
PARTIAL 2
PARTIAL 3
DISARMED
Disable this function if this signalling is not used.
The light alerts enabled causes higher battery consumption.
DIP6
NOT USED
DIP7
NOT USED
DIP8
NOT USED
4. RESET
It is possible to reset the siren to factory settings with the following steps:
1. Unplug the battery
2. Set all DIPs to ON
3. Connect the battery: the siren emits some "BEEP" and LED blinking
4. Unplug the battery and set all DIPs to OFF, the start with new programming
> long blink
> long blink + 1 short
> long blink + 2 short
> long blink + 3 short
> three blinks
OFF
Normal working
Normal working
Supervision off
Block Enabled
Alerts ON
Leave OFF
Leave OFF
Leave OFF
4
ON
Learning
Learning
(press the temper
switch to start)
Supervision on
Block Disabled
Alerts OFF
-
-
-