Duevi RX2AP Instrukcja instalacji i użytkowania - Strona 2

Przeglądaj online lub pobierz pdf Instrukcja instalacji i użytkowania dla Odbiornik Duevi RX2AP. Duevi RX2AP 4 stron. Two outputs radio receiver

2.
TECHNICAL
RELAY OUTPUTS
2 alarm relays (mono-stable or bi-stable working modes)
MAX: 24 V
SIGNALLING
Buzzer on board for operation feedback (not excludible)
4 internal LEDs for operation feedback (2 LEDs for relay outputs state, 2 LEDs for Radio Zones management)
RADIO RECEIVER
Working frequency: 433.92 MHz – Radio code format: 48 bit
POWER SUPPLY
12 V
WARNING > The receiver must be powered by a very low voltage power source (SELV)
DIMENSION
120 x 85 x 28 mm
COMPATIBILITY
Sensors (only AN models): MINI-M, MINI-C, CTSR, DIRRV2, DIRRPV, DSA, DSF, E-WALL, DIRRVE, DIRRVE-DT, MOSKITO
Remote controls: TXS/M
Siren Transmitters: TSR
3.
LEARNING
1 To enter in learning mode set DIP1 to ON. Two "beep" are emitted
LED_A lights on meaning the receiver is in memory space for Relay A (Radio Zones A-1 ÷ A-5).
2
The receiver starts from Radio Zone A-1. If the memory position is empty the LED_O (free memory) lights on, if
occupied the LED_X (used memory, it is possible to overwrite) lights on.
To go to the next Radio Zone, press P.
3
As confirm the receiver emits as many "beep" as the Radio Zone number (Radio Zone A-2 = 2 "beep", Radio
Zone A-3 = 3 "beep"...).
/ 500 mA
/ MAX 25 mA
+12
Power supply: positive reference +12V
GND
Power supply: ground/negative reference
C1
Relay A: common terminal
NC1
Relay A: Normally Closed terminal
NA1
Relay A: Normally Opened terminal
C2
Relay B: common terminal
NC2
Relay B: Normally Closed terminal
LD
LED output: combined to Relay A activation
Output at +12V when the Relay A is active – Output at zero when Relay A is at rest.
Useful to visualize (using a TSR) the arming status of a control panel.
TMP
TAMPER output, Open Collector – Close to negative to signal the reception of a
tamper radio code from a sensor. In case of tamper alarm, also the Relay output
combined to the sensor will be activated.
LWB
LOW BATTERY output (sensors), Open Collector – Close to negative to signal the
reception of a Low Battery code from a sensor.
OFF
Normal working
DIP1
ON
LEARNING (pairing of radio devices)
OFF
Relay A = Monostable
DIP2
ON
Relay A = Bistable
OFF
Normal working
DIP3
ON
"LIGHT TIMER" mode
OFF
"Sensors + Remote controls" mode or use with TSR
DIP4
ON
"Remote controls" mode
2
LED_A
LED_B
LED_X
Yellow
Green
Blue
2x BEEP
OR
1x BEEP ... 5x BEEP
LED_O
Red