NOTE: UL Classified Kits require installation by qualified
personnel only without major disturbance, cutting, splicing or
soldering of factory installed wiring.
WARNING: To reduce risk of fire, replace only
with the same type and ratings of fuse. The
fused power cable is polarity sensitive. The
positive wire must be connected to a positive
power source.
8
Connect wires from the control handle switch and solenoid
valve terminals to the truck electrical system. The fuse
must be connected to an unswitched positive terminal. The
solenoid must be able to energize with the truck key in the
off position.

Operation

• Sideshift left and right several times.
• Engage the fork position function by pressing the solenoid
button. Open and close the forks several times.
• Check for operation in accordance with ANSI standards
shown below.
• Check for leaks at the fittings, valve and cylinders.
GA0010.eps
Tilt Forward
Hoist Down
A
B
Hoist Up
Tilt Back
Control Handle Switch–
Use Control Knob Kit 6823292 (12V) OR 6823293 (24V-48V)
OR
Low Profile Switch Kit 6818564 (12V) OR 6818622 (24V-48V)
Diode
Solenoid
Valve
B
B
A
FP0870.eps
SIDESHIFT and
SOLENOID ACTIVATED
FORK POSITIONING
A Sideshift Left – Forks Out (press button)
B Sideshift Right – Forks In (press button)
4
Fuse
Unswitched
Truck
Fuse Block
Truck
Battery
AC1212.eps
B
A
A