3P Technik 1000515 Instrukcja obsługi i montażu - Strona 3
Przeglądaj online lub pobierz pdf Instrukcja obsługi i montażu dla Systemy filtracji wody 3P Technik 1000515. 3P Technik 1000515 4 stron. Rainwater filter for installation into tanks or in the ground
Installation of a Volume Filter VF1
How it works:
1. As water arrives the level builds up and is
equally distributed across the cascade
2. Pre-cleaning through the cascades.
Largest dirt particles are led across the
primary filter cascades directly to the
stormwater.
3. Pre-filtered water then flows over the
secondary filter sieve
(mesh size 0.65 mm). Due to the
special mesh structure of the sieve,
any dirt washes directly into the
stormwater. Very low maintenance.
Installation advice 3P Volume Filter VF1:
• Connections to the 3P Volume Filter VF1 can be made with universal connectors.
• Rainwater enters through the upper inlets, at DN 100.
• For roof areas up to 175 m² connect from either right or left.
• For roof areas above 175 m² we recommend you connect from both sides,
in order to obtain the maximum filter efficiency.
• Saw off 1 cm from the outside of the selected inlet(s).
• Cleaned water is led via the outlet at DN 100 to the storage tank.
• Dirty water goes via the outlet at DN 125 to waste.
• Install the 3P Volume Filter VF1 horizontally on a level stable surface. For deeper installations
the 3P Telescopic Extension can be used to reach ground level.
Installation of a
Volume Filter VF1 trafficable
4. Cleaned water flows to storage
5. Dirt goes to the stormwater
5. Dirt goes to the stormwater
inlet rainwater
DN 100
cleaned water to stor-
age tank DN 100
4
be made with universal connectors.
inlet rainwater
DN 100
1
2
3
dirty water to
stormwater DN 125
5