Danfoss ADAP-KOOL AK-PC 781 Podręcznik użytkownika - Strona 12

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Kontroler Danfoss ADAP-KOOL AK-PC 781. Danfoss ADAP-KOOL AK-PC 781 14 stron. Capacity controller with heat recovery

Danfoss ADAP-KOOL AK-PC 781 Podręcznik użytkownika
High P0
High Pc/Sd
Hpcontrol / Receive
Superheat Min/Max
Load shedding
P0/S4/Pctrl error
Misc. sensors
Comp. common safety
Comp. VSD safety
Comp. 1 safety
Comp. 2 safety
Comp. 3 safety
Comp. 4 safety
Comp. 5 safety
Comp. 6 safety
Comp. 7 safety
Comp. 8 safety
Pc/S7 sensor error
Blocked air flow
Fan safety
Comp. Low Oil lvl
Comp. High Oil lvl
Oil Separator alarm
Oil Receiver alarm
Oil Recv High press
Oil Recv. Low press
Tw boiling alarm
Hr boiling alarm
General alarm inputs
Measurements
AK error
Comp. ctrl. temp °C
Comp. ctrl. ref. °C
Compressor cap. %
Request Compr. Cap %
P0 °C
Ss Suction gas °C
Cond. ctrl. temp °C
Cond. ctrl. ref. °C
Cond. cap. %
Request Cond. cap %
Pc Bar
Tc °C
Gc status
Pgc Bar
Pgc reference Bar
Sd discharge gas °C
Sgc °C
DI 1 input
DI 2.... Input
Settings
Main switch
DI 1 Alarm delay m
DI 2.... Alarm delay m
12
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
0/1/2/3/4
When "ON", the controller is in alarm condition.
Actual temperature for control sensor (Po or S4)
Actual reference temp. for compressor capacity
(incl. external reference signal, if any)
Cut-in compressor capacity in % (of total capacity)
Reference for compressor capacity (deviations may be due to time delays)
Suction pressure in °C. (Measured with the pressure transmitter)
Actual suction gas temperature
Actual temperature for control sensor (Pc or S7)
Actual reference temp. for condenser capacity
(incl. external contributions, if any)
Cut-in condenser capacity in % (of total capacity)
Reference for condenser capacity
Condensing pressure (measured with the pressure transmitter)
Condensing pressure in °C. (measured with the pressure transmitter)
Actual gas cooler operation:
0=Off. 1=Standby. 2=Max COP operation. 3=Heat recovery. 4=Extra capacity.
5=Manual control.
Actual gas cooler pressure
Actual reference for gas cooler pressure
Actual discharge gas temperature
Actual temperature at outlet from the gas cooler
Alarm status on the function defined as a DI1 alarm
ON: Alarm is activ
OFF: No alarm, normal situation
As above, but for the alarm functions 2 to 6
Main switch:
Time delay for the alarm "DI 1 Alarm"
As above, but for the alarm functions 2 to 6
Menu operation
RC8CE202 © Danfoss 03/2013
ON:
Regulation
OFF: Controller stopped
AK-PC 781 Version 4.1x